13
Integrated braking resistor BW1
Technical Data and Dimension Sheets
13.2 Integrated braking resistor BW1
The following diagram shows the load capacity per braking operation of the BW1 braking
resistor integrated in MOVIGEAR
®
as standard:
13.2.1 Calculation example
The known values are:
• Average braking power: 144 W
• Brake ramp: 2 s
• 200 brake applications per hour
Calculating the energy from the power of the brake ramp:
The brake ramp [3] (0.2 s) can be used for the brake ramp in the diagram. Use the
characteristic curve with the shorter brake ramp because a shorter brake ramp means
more power.
The diagram allows a power of 290 J with a 0.2 s brake ramp at 200 cycles per hour. In
this case, the required 288 J can be dissipated with BW1.
2393524363
[1] Brake ramp 10 s
[2] Brake ramp 4 s
[3] Brake ramp 0.2 s
c/h cycles per hour
200
3
00
400
500
600
[J]
[1]
[2]
[3]
0
100
0
10
50
100
200
500
1000
2000
3
000
4000
5000
6000
[c/h]
776982283
W
P t
W
W
s
W
J
= ×
=
×
=
144
2
288
P
i
f
kVA
Hz
n
Summary of Contents for MOVIGEAR DAC B