![SEW-Eurodrive MOVIGEAR DAC B Operating Instructions Manual Download Page 206](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343206.webp)
206
Operating Instructions – MOVIGEAR® DAC-B
13
Technical data of MOVIGEAR
®
Technical Data and Dimension Sheets
13.1.3 Binary inputs/signal relay
13.1.4 Derating factors for MGF..4 and MGF..4/ET
For MOVIGEAR
®
MGF..4 and MGF..4/ET, you have to additionally observe the I
N
re-
duction shown in the following figure:
MOVIGEAR
®
type
MGF..2
MGF..4
MGF..4/ET
Input type
DI01 to
DI04
Isolated via optocoupler; PLC compatible to EN 61131-2
(digital inputs type 1)
R
i
≈
3.0 k
Ω
, I
E
≈
10 mA, sampling interval
≤
5 ms
Number of inputs
4
Signal level
+15 to +30 V = "1" = Contact closed
–3 to +5 V = "0" = Contact open
Signal relay
Contact information
K1a
Response time
≤
15 ms
DC 24 V / 50 mA / DC 12 to IEC 60947-5-1
(only SELV or PELV circuits)
K1b
Signaling function
NO contact for ready signal
Contact closed:
– with voltage present (24 V system)
– if no fault was detected
– after completion of self-testing phase (when
unit is turned on)
2859291275
[1]
Ambient temperature
≤
35 °C
[2]
Ambient temperature = 40 °C
Input current [% I
N
]
1000
100
90
80
70
60
1500
2000
Motor speed n
e
[rpm]
[
1
]
[
2
]
INFORMATION
Derating is based on typical operating conditions with a supply voltage of 24 V (AS-
Interface electronics supply, signal level of binary inputs, input voltage of STO input).
P
i
f
kVA
Hz