![SEW-Eurodrive MOVIGEAR DAC B Operating Instructions Manual Download Page 170](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343170.webp)
170
Operating Instructions – MOVIGEAR® DAC-B
9
Transmitting individual parameters via AS-Interface
Communication with AS-Interface Double Slave GLK31A
The response of the MOVILINK
®
protocol is evaluated with the "Read request" service
as follows to make sure that the MOVIGEAR
®
inverter has changed parameter
8807.0
.
"Read request" service:
The slave replies after the system-related telegram runtime.
"Read response OK" response telegram:
Setting ramp t11
down
Set ramp t11 down (parameter
8808.0
) to 0.5 s. The ramp time for ramp t11 down is set
in the same way as the ramp time for ramp t11 up.
Ramp t11 down has index 8808
dec
= 0x2268 and subindex 0.
CTT2 service
Code
Index Length
0x10
0x02
0x09
Code 0x10 =
Read request
Index 0x02 =
MOVILINK
®
parameter service
Length 0X09 =
Length of the MOVILINK
®
protocol
CTT2 service
MOVILINK
®
protocol
Code
Addres
sing
Man-
age-
ment
Sub-
index
Index
high
Index
low
MSB
data
Data
Data
LSB
data
0x50
0x00
0x32
0x00
0x22
0x67
0x00
0x00
0x00
0x00
Code 0x50 =
Read response OK
Addressing 0x00 =
Addressing the command pcb because this is where the parameter is stored.
Management 0x32 =
Write parameter => no MOVILINK
®
error
Subindex 0x00 =
Subindex of the parameter
Index High 0x22 =
High value of the index
Index Low 0x67 =
Low value of the index
=> Index of parameter = 8807
dec
= 0x2267
hex
The value 0x2267
hex
is written on bytes Index High and Index Low.
Data MSB 0x00
If the MOVILINK
®
service has been executed correctly, the data byte value is
0x0 = 0
dec
Data 0x00
Data 0x00
Data LSB 0x00