5
Appendix
Connection variants
Manual – MOVIGEAR
®
B
24
5.2
Connection variants
5.2.1
Position of the terminals for safe torque off (STO)
The following figure shows
an example
of the terminal positions at MGF..-DSC-B for
safe torque off (STO) of MOVIGEAR
®
:
PE
PE
PE
PE
1
11 12
15
2
5
2552708747
5.2.2
Assignment of the terminals for safe torque off (STO)
The following figure shows the terminal assignment for safe torque off (STO) of
MOVIGEAR
®
:
Assignment
No.
Name
Color
Function
1
STO +
Yellow
Input STO +
2
STO −
Yellow
Input STO –
11
STO +
Yellow
Output STO + (to loop through)
12
STO −
Yellow
Output STO – (to loop through)
INFORMATION
For information about looping STO through, refer to chapter "Connecting an external
safety relay for STO".
Connection cable
INFORMATION
Use only shielded cables for this connection.
22746250/EN – 12/2016