28
Manual – MOVIFIT® SNI Fieldbus Gateway UFF41B for MOVIGEAR® SNI
5
General information
Startup
5
Startup
5.1
General information
Correct project planning and installation are the prerequisites for successful startup. For
detailed project planning information, refer to the chapter "Project Planning" in this
document, and to the documentation for MOVIFIT
®
SNI and MOVIGEAR
®
SNI.
Check the installation by means of the installation information in the MOVIFIT
®
SNI,
MOVIGEAR
®
SNI operating instructions, the UFF41B fieldbus gateway manual, and the
manual at hand (refer to the chapter "System Description").
5.2
SNI gateway configuration
General
information
• Start MOVITOOLS
®
MotionStudio.
• From the "Startup" context menu, choose "SNI gateway configuration" The initial
screen of the SNI Gateway Configurator will open (see figure below).
The SNI gateway configuration allows for distributing the available 64 process data
words to the individual MOVIFIT
®
SNI and MOVIGEAR
®
SNI units depending on the
required function. The buttons have the following meaning:
• [Start Up] button: Start the SNI gateway configuration
• [Monitor] button: Process data monitor with integrated control function
• [Diagnose] button: Diagnostics of the fieldbus gateway and the configured
MOVIFIT
®
SNI and MOVIGEAR
®
SNI units
12140AEN
0
0
I