20
Manual – MOVIFIT® SNI Fieldbus Gateway UFF41B for MOVIGEAR® SNI
3
Process data assignment for fieldbus control
Project Planning
3.6
Process data assignment for fieldbus control
The fieldbus gateway can be integrated into a PROFIBUS controller using the GSD file
"SEW_600D.GSD", or into a DeviceNet controller using the EDS file
"SEW_GATEWAY_UFF.EDS".
INFORMATION
The latest version of the GDS and EDS files are available on the SEW homepage
(http://www.sew-eurodrive.com) under the heading "Software".
Gateway 1 PD
PO
PI
Assignment
Bit 0
SNI controller 1 timeout
Bit 1
SNI controller 2 timeout
Bit 2
SNI controller 3 timeout
Bit 3
SNI controller 4 timeout
Bit 4
SNI controller 5 timeout
Bit 5
SNI controller 6 timeout
Bit 6
Warning
Bit 7
Error
Bit 8 - 15
•
Status (if bit 6 = bit 7 = FALSE)
•
Error number (if bit 7 = TRUE)
•
Warning (if bit 6 = TRUE AND bit 7 = FALSE)