16
Manual – MOVIFIT® SNI Fieldbus Gateway UFF41B for MOVIGEAR® SNI
3
Addressing
Project Planning
3.4.3
MOVIFIT
®
SNI via Address Editor
Opening the
Address Editor
You can use the Address Editor once MOVITOOLS
®
MotionStudio has been installed.
Do the following to open the Address Editor:
1. Close MOVITOOLS
®
MotionStudio.
2. Open the Address Editor in the WINDOWS
®
start menu by following the path below:
Start\Program\SEW\MOVITOOLS MotionStudio\Address Editor
(Address Tool)
Searching for
Ethernet stations
You can use the Address Editor to find Ethernet stations in a network. This is especially
useful for finding recently added Ethernet stations. The Address Editor also helps you
to locate the Ethernet interface of the Ethernet stations that were found.
To search for Ethernet stations and locate hardware, proceed as follows:
1. Make sure that MOVIFIT
®
SNI is connected with the PC via an Ethernet network.
Select "Ethernet" as the interface for PC and unit. To do so, click on the
corresponding option field in the lower part of the window.
2. Click [Next] to confirm your selection and proceed to the next dialog.
3. Wait for the network scan to start
automatically
. The default setting for the waiting
time (scan timeout) is 3 seconds [2]
12132AEN