Operating Instructions – MOVIFIT
®
-FC
5.10 Fieldbus systems connection examples
5.10.1 PROFIBUS
Via terminals
The following figure shows the PROFIBUS connection via terminals:
• If MOVIFIT
®
is located at the end of a PROFIBUS segment, it can only be connected
to the PROFIBUS mains by the incoming PROFIBUS line.
• To prevent malfunctions in the bus system due to reflections, etc., the PROFIBUS
segment must be terminated at the first and last physical stations with bus termi-
nating resistors.
• The bus terminating resistors are already installed in the MOVIFIT
®
-ABOX and they
can be activated using the S1 switch.
TIP
The example applies for the following connection box:
• Standard ABOX "MTA...-S02.-...-00"
• Hybrid ABOX "MTA...-S42.-...-00"
812474507
[1]
[2]
DIP switch S1 for bus termination
Shield plate, see section "Connecting the PROFIBUS line" (see page 47)
MOVIFIT
®
X30
S1
MOVIFIT
®
X30
S1
[1]
[1]
MOVIFIT
®
A_IN
X30
X31
X31
X31
B_IN
A_OUT
B_OUT
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
[2]
[2]
[2]
[2]
[2]
PROFIBUS DP
PROFIBUS DP
PROFIBUS DP
IN
OUT
IN
OUT
IN
OUT
S1
[1]
A
B
A_IN
B_IN
A_OUT
B_OUT
A_IN
B_IN
A_OUT
B_OUT
ON