6
Startup
Startup MOVIFIT®
Operating Instructions – MOVIFIT
®
-FC
103
6.3.3
Startup with DeviceNet
1. Check the MOVIFIT
®
connection.
2. Set the DeviceNet address at DIP switch S2 of the MOVIFIT
®
-ABOX.
3. Set the baud rate at DIP switch S2 of the MOVIFIT
®
-ABOX:
4. To start up the MOVIFIT
®
inverter, see the section "Startup MOVIFIT
®
Frequency
Inverter" (see page 104).
5. Mount the MOVIFIT
®
-EBOX on the ABOX and close it.
6. Switch on the 24V_C and 24V_S supply voltage(s). The associated control LEDs
should now light up green.
Setting DeviceNet
address (MAC ID)
and baud rate
The DeviceNet address is set using DIP switches S2/1 to S2/4. The baud rate is set
using DIP switches S2/7 and S2/8.
The following table uses address 9 as an example to show how to determine the DIP
switch settings for any bus address.
The following table shows how to set the baud rate using DIP switches S2/7 and S2/8:
837570443
[1] Baud rate setting
[2] DeviceNet address setting
DIP switch setting
Value
DIP S2/1 =ON
1
DIP S2/2 = OFF
2
DIP S2/3 = OFF
4
DIP S2/4 =ON
8
DIP S2/5 = OFF
16
DIP S2/6 = OFF
32
Baud rate
Value
DIP S2/7
DIP S2/8
125 kbaud
0
OFF
OFF
250 kbaud 1
ON
OFF
500 kBaud
2
OFF
ON
(Reserved)
3
ON
ON
1
ON
6
7
5
4
3
2
8
S2
[2]
2 x 0 = 0
2 x 0 = 0
5
4
2 x 1 = 8
2 x 0 = 0
2 x 0 = 0
2 x 1 = 1
3
2
1
0
2 x 1 = 2
2 x 0 = 0
1
0
9
2
[1]
0
0
I
Summary of Contents for MOVIFIT-FC
Page 2: ...SEW EURODRIVE Driving the world ...
Page 169: ......
Page 170: ......
Page 171: ...SEW EURODRIVE Driving the world ...