![SEW-Eurodrive MOVI-PLC advanced Manual Download Page 13](http://html.mh-extra.com/html/sew-eurodrive/movi-plc-advanced/movi-plc-advanced_manual_1250107013.webp)
Manual – MOVI-PLC® advanced Controller Remote Maintenance via ORA11B
13
4
Connections and terminals at the front of ORA11B
Assembly and Installation Notes
4.3
Connections and terminals at the front of ORA11B
The following figure shows the connections and control elements of the ORA11B option
necessary for remote maintenance.
4.3.1
Reset button
64063AXX
[1] Reset button
[2] Telephone connection (RJ45 plug connector)
[3] 4-port Ethernet switch (LAN 1 - LAN 4) for network connection
[4] Power LED
[5] COM LED
[6] Data LED
[7] Status LED
ORA11B
RJ45/Line
LAN 2
1
Power
Reset
COM
Data
Status
LAN 4
LAN 1
LAN 3
3
4
2
[1]
[2]
[3]
[4]
[5]
[6]
[7]
Operation
Meaning
Press once briefly
Resets ORA11B via software and restarts it.
Hold for at least 3 seconds
Resets the hardware of ORA11B and restarts it.
Pressing it 3 times in quick succession
within 2 seconds
Deletes all settings of ORA11B and resets the unit to the
factory settings.