![SEW-Eurodrive MOVI-C UHX45A Series Manual Download Page 39](http://html.mh-extra.com/html/sew-eurodrive/movi-c-uhx45a-series/movi-c-uhx45a-series_manual_1250103039.webp)
4
Installation notes
Electrical installation
Manual – MOVI-C
®
CONTROLLER advanced with PROFINET IO Fieldbus Interface
39
4.3.6
CAN system bus connection
In preparation
4.3.7
Connecting the fieldbus slave
The MOVI‑C
®
CONTROLLER serves as fieldbus slave for the PLC (fieldbus master).
The communication is realized via Ethernet.
The MOVI‑C
®
CONTROLLER is connected to the Ethernet network via the following
terminals:
•
X40 (RJ45 connector)
•
X41 (RJ45 connector)
The device is connected to the other network stations, using a category 5, class D
twisted-pair cable in accordance with IEC 11801, edition 2.0.
L/A
X80
X40
US1
BF
X85
L5
L6
L/A
X41
L/A
UHX45A-N
S3
T1
XM
L1
L2
L3
L4
X40
L/A
X41
L/A
9007220298082955
INFORMATION
According to IEEE 802.3, 200 Edition, the maximum cable length for
10 MBaud/100 MBaud Ethernet (10BaseT/100BaseT) between 2 network nodes is
100 m.
24777730/EN – 01/2018