
11
Supplementary field distributor startup information
MOVIMOT® inverter integrated in field distributor
Manual – EtherCAT
®
Interfaces, Field Distributors
89
11.3.3
Internal wiring of the MOVIMOT
®
inverter in the field distributor
2
4
V
T
H
L
R
1
3
1
4
1
5
L
1
L
2
L
3
L
1
L
2
L
3
2
4
V
TH
[4]
[1]
[2]
[3]
X4
ϑ
9007200441675147
[1] DIP switches for setting the connection type (
W
or
m
)
Make sure that the connection type of the connected motor corresponds
with the setting of the DIP switch.
[2]
Note the enabled direction of rotation
(Both directions of rotation are enabled as standard)
Both directions of rota-
tion are enabled
Only
CCW
direction of
rotation is enabled
Only
CW
direction of rotation is
enabled
24V
TH
L
R
24V
TH
L
R
24V
TH
L
R
TH
TH
TH
ϑ
ϑ
ϑ
[3] Connection for internal braking resistor (in motors without brake only)
[4] Maintenance switch
11.4
MOVIMOT
®
inverter integrated in field distributor
MOVIMOT®
inverter
integrated
in field
distributor
The following chapter describes the differences in the use of the MOVIMOT
®
inverter
integrated in the field distributor compared to use when it is integrated in the motor.
11.4.1
Different factory settings for MOVIMOT
®
integrated in the field distributor
Note the changes to the factory settings (in bold) when using
MOVIMOT
®
integrated in
Z.7. or Z.8 field distributors:
DIP switch S1
S1
1
2
3
4
Meaning
RS485 address
2
0
2
1
2
2
2
3
MOVIMOT
®
1
ON
1
1
1
1
OFF
0
0
0
0
25809148/EN – 01/2019