Operation

Local mode depending on switch position

Addendum to the Operating Instructions – GBG10..A..

15

5.3

Local mode depending on switch position

The  following  table  provides  an  overview  of  drive  unit  operation  depending  on  the
switch position of the CBG10..A keypad:

Button position

Drive unit 

operation

Brake/DynaStop

® 

control

"MODE"

Rotary

switch

"SPEED" "BRAKE" "RESET"

AUTO

X

Automatic mode

Control via bus, ...

by drive unit

LOCAL

STOP

X

AUTO

0

Local mode

Stop, no enable

by drive unit

LOCAL

CCW

f1

AUTO

0

Local mode

CCW rotation with f1

by drive unit

LOCAL

CCW

f2

AUTO

0

Local mode

CCW rotation with f2

by drive unit

LOCAL

CW

f1

AUTO

0

Local mode

CW rotation with f1

by drive unit

LOCAL

CW

f2

AUTO

0

Local mode

CW rotation with f2

by drive unit

LOCAL

STOP

X

MANUAL

0

Local mode

Stop, no enable

Manual

X

Drive fault

1)

Brake applied.

DynaStop

®

 is active.

LOCAL

STOP

X

0 → 1

2)

Fault reset 

after drive fault

by drive unit

1) Fault on the drive unit.

2) Fault reset by pressing the "RESET" button.

X = any switch position

23569654/EN – 07/2017

Summary of Contents for GBG10 A Series

Page 1: ...23569654_0717 Drive Technology Drive Automation System Integration Services Addendum to the Operating Instructions Keypad GBG10 A Edition 07 2017 23569654 EN...

Page 2: ...SEW EURODRIVE Driving the world...

Page 3: ...licable documentation 6 2 Device structure 7 2 1 GBG10 A keypad 7 2 2 Type designation 9 3 Electrical installation 10 3 1 Connecting the GBG10 A keypad 10 4 Startup 11 4 1 Startup notes 11 4 2 Activat...

Page 4: ...ng table shows the grading and meaning of the signal words for safety notes Signal word Meaning Consequences if disregarded DANGER Imminent hazard Severe or fatal injuries WARNING Possible dangerous s...

Page 5: ...ushing Warning of suspended load Warning of automatic restart 1 2 3 Structure of embedded safety notes Embedded safety notes are directly integrated into the instructions just before the de scription...

Page 6: ...age to equipment or property resulting from non observance of these operating instructions In such cases SEW EURODRIVE assumes no liability for defects 1 5 Product names and trademarks The brands and...

Page 7: ...example of keypad GBG10 11A 00 MODE AUTO MODE LOCAL SPEED f1 SPEED f2 BRAKE AUTO BRAKE MANUAL MOVIGEAR R DRC CONTROLLBOX SNI DSC DAC RESET STOP RESET CW CCW 2 3 1 20736929419 1 M23 plug connector 2 C...

Page 8: ...ts For connecting the keypad to the drive unit the drive unit must be equipped with the following plug connector X5131 SNI or DSC designs X5132 DAC designs To operate the drive unit in local mode with...

Page 9: ...AR DRC 13575848 2015 1000001 Supply voltage Rated current Maximum current Protection type Temperature 24 V DC 40 mA 60 mA IP20 25 60 C 20738431115 2 2 2 Type designation The following table shows the...

Page 10: ...t connection of keypad and drive unit The GBG10 A keypad is not designed for permanent connection within a system Damage to the device Disconnect the keypad from the drive unit after use and remove it...

Page 11: ...of crushing due to possible restart after re establishment of the power supply or presence of the signals at the STO inputs Severe or fatal injuries In emergency situations switch the MODE switch to A...

Page 12: ...ode is not possible with this setting When DIP switch S2 3 is set to ON you can control the drive unit in automatic mode bus control or local mode depending on the position of the MODE switch 4 2 1 Re...

Page 13: ...nhibited From version 16 From version 14 OFF S2 ON 1 2 3 4 Inhibited ON S2 ON 1 2 3 4 Enabled or inhibited 1 Required drive status for switching to local mode 4 4 Setting the speed setpoints Set the s...

Page 14: ...mode take measures to prevent the drive unit from starting up unintentionally e g by activating STO Observe the requirements for local mode in chapter Startup 5 2 Control elements The following figure...

Page 15: ...rive unit LOCAL STOP X AUTO 0 Local mode Stop no enable by drive unit LOCAL CCW f1 AUTO 0 Local mode CCW rotation with f1 by drive unit LOCAL CCW f2 AUTO 0 Local mode CCW rotation with f2 by drive uni...

Page 16: ...tor P insert SpeedTec cap able company Intercontec male 0 coded Cable length 1 m Interference immunity Meets EN 61800 3 2 Environment Interference emission Meets category C1 according to EN 61800 3 Am...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...SEW EURODRIVE Driving the world SEW EURODRIVE GmbH Co KG P O Box 3023 76642 BRUCHSAL GERMANY Phone 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com www sew eurodrive com...

Reviews: