4
Startup
Activating local mode using DAC units
Addendum to the Operating Instructions – GBG10..A..
13
4.3
Activating local mode using DAC units
When using DAC drive units, you need not activate local mode with the CBG10..A
keypad.
4.3.1
Requirements for local mode
The following requirements must be met for operating and switching the unit to local
mode:
Requirements on
the drive unit
Firmware for command PCB
Setting
DIP switch
S2/2
Drive status
1)
MOVIGEAR
®
DAC-B
DRC..
DAC
Versions .11 to .15
Versions .10
to .13
"OFF"
S2
ON
1
2 3 4
Inhibited
From version .16
From version .14
"OFF"
S2
ON
1
2 3 4
Inhibited
"ON"
S2
ON
1
2 3 4
Enabled
or inhibited
1) Required drive status for switching to local mode
4.4
Setting the speed setpoints
Set the speed setpoints at the following speed setpoint sources:
Drive unit
type
Startup mode
Speed setpoint source
n_f1
n_f2
DAC
Easy
Setpoint poten-
tiometer f1
Factory setting:
2000 min
-1
Setpoint poten-
tiometer f2
Factory setting:
0 (200 min
-1
)
Expert
1)
Parameter index
10096.35
Factory setting:
1500 min
-1
Parameter index
10096.36
Factory setting:
0 (200 min
-1
)
DSC
—
SNI
—
1) Control elements f1/f2 are disabled.
For more information refer to the chapter "Startup" in the respective "MOVIGEAR
®
.."
or "DRC.." operating instructions.
23569654/EN – 07/2017