4
Mechanical installation
Cover
Assembly and Operating Instructions – Explosion-Proof Gear Units
73
4.13
Cover
CAUTION
Risk of injury due to rotating input and output elements during operation.
Risk of jamming and crushing.
•
Equip the input and output elements with a touch guard.
INFORMATION
Observe the following points during installation:
•
The seal must not be damaged.
•
The glued connection between gasket and cover must be flawless.
•
The bores of the gasket and the cover must match.
4.13.1
Mounting the fixed cover
Proceed as follows:
1. Remove the plastic plug on the gear unit housing (see figure 1).
1
2
9007199273238539
2. Use the delivered screws to mount the cover to the gear unit housing (see figure
2).
4.13.2
Operation without cover
In certain application cases, e.g. with a through-shaft, a cover cannot be installed. The
cover is not necessary if the system or unit manufacturer provides corresponding com-
ponents to guarantee for compliance with the required degree of protection. If this res-
ults in additional maintenance, the manufacturer has to describe this in the operating
instructions for the system or component.
24804134/EN – 05/2018