7
Mounting positions
Mounting position sheets
Assembly and Operating Instructions – Explosion-Proof Gear Units
140
Displayed shaft
Observe the following information regarding the illustrations on the mounting position
sheets:
INFORMATION
For gear units with solid shaft:
The displayed shaft is always on the A-side.
For shaft-mounted gear units:
The shaft with dashed lines represents the customer
shaft. The output end ( = shaft position) is always shown on the A-side.
7.6.2
Position of the oil level plug of compound gear units
To ensure sufficient lubrication of the first gear unit (larger gear unit) in case of com-
pound gear units, the following gear units have a higher oil level in the specified
mounting positions:
•
Helical gear unit type R..R in mounting position M1 and M2
•
Helical-worm gear unit type S..R in mounting position M3
The oil level plugs are located at the following positions, deviating from the specifica-
tions on the mounting position sheets:
S..R..
SF..R.., S.F..R..,
SA..R..
2
R..R..
15987248395
Icon
Meaning
Oil level plug
24804134/EN – 05/2018