Before you start
Mechanical Installation
4
Mechanical Installation
4.1
Before you start
The drive may only be installed when
• the specifications on the drive's nameplate and the output voltage of the frequency
inverter match the voltage supply system
• The drive is undamaged (no damage caused by transportation or storage).
• you are certain that the following requirements have been fulfilled:
– Ambient temperature between -20 °C and 40 °C
1)
– No oil, acid, gas, vapors, radiation, etc.
– Installation altitude max. 1000 m above sea level
– Note the restrictions for encoders
– Special versions: Drive configured in accordance with the ambient conditions
4.2
Mechanical installation
4.2.1
Preliminary work
Motor shaft ends must be thoroughly cleaned of anti-corrosion agents, contamination or
similar (use a commercially available solvent). Do not allow the solvent to penetrate the
bearings or shaft seals – this could damage the material.
Motors with rein-
forced bearing
NOTE
Do observe the safety notes in chapter 2 (see page 7) for when installing the unit!
1) Note that the temperature range of the gear unit may also be restricted (see gear unit operating instruc-
tions).
STOP
The mounting position for installation must correspond to the specifications on the
nameplate.
STOP
Motors with a reinforced bearing must not be operated without an overhung load. Oth-
erwise you risk damaging the bearings.