Manual – MOVI-PLC® advanced DHR41B for EtherNet/IP, Modbus/TCP and PROFINET IO
7
Configuration of the master (Modbus scanner)
Configuration and Startup (Modbus/TCP)
Settings for the
Ethernet
component
• Double-click on the Ethernet component to open the configuration window.
• If you have a non-extendable rack, enter a "1" in the "Network" input field in the
"XWAY address" section.
• Enter the number of the slot that the Ethernet component is plugged into (here: 2) in
the input field "Station" in the "XWAY address" section. In this case, the XWAY ad-
dress is 1.2.
• In the section "IP address configuration" select the radio button "Configured". Enter
the IP address and the network parameters in the input fields "IP address", "Subnet-
work mask" and "Gateway address". If the control system is to receive the address
parameters via a DHCP server, select the radio button "Client/Server configuration"
in the section "IP address configuration".
• In the "Ethernet configuration" section, select the radio button "Ethernet II".
• In the "Module utilities" section, select the check box "IO Scanning".
10816AXX