24
Operating Instructions – Explosion-Proof CMP Synchronous Servomotors
5
Connecting the CMP servomotor
Electrical Installation
5.4
Connecting the CMP servomotor
5.4.1
Procedure
• Connect the servomotor according to the enclosed wiring diagram.
• Check whether the cable cross sections comply with:
• The rated motor current
• The applicable installation instructions
• The requirements of the place of installation
• Screw on the connections and PE conductors.
• Check the winding connections in the terminal box and tighten them, if necessary.
5.4.2
Wiring diagrams
The following applies to all wiring diagrams:
• View on wiring side
• Colors according to SEW-EURODRIVE cable:
NOTE
The servomotor must only ever be connected as shown in the following wiring diagram,
which is also included with the servomotor.
Color code
Color
BK
Black
BN
Brown
BU
Blue
GN
Green
GY
Gray
OG
Orange
PK
Pink
RD
Red
VT
Violet
WH
White
YE
Yellow
GY / PK
Gray/pink
RD / BU
Red/blue
BK / WH
Black/white
RD / WH
Red/white