5
Electrical installation
Connecting the plug connectors – Single-cable technology for CM3C.. motors in encoderless design
Operating Instructions – CM3C63 – 100
45
5.7.2
Connecting the SH1 power plug connector (M23) without brake/with brake
The wiring diagram of the plug connector depicts the contact end of the connections.
Function
Motor connection for motors in encoderless design
Connection type
M23, male, male thread, TE Connectivity - Intercontec Products, series 723, SEW in-
sert, SpeedTec equipment, coding ring: without, protected against contact
Connection diagram
U
V
W
A
B
C
D
H
L
PE
34609095051
Assignment for motor without brake
Contact
Signal
Description
U
U
Motor connection phase U
V
V
Motor connection phase V
W
W
Motor connection phase W
A
Reserved
Do not connect
B
Reserved
Do not connect
C
Reserved
Do not connect
D
Reserved
Do not connect
PE
PE
PE connection
H
H
Motor protection
L
L
Motor protection
Assignment for brakemotors with BK../BZ..D brake in encoderless design
Contact
Signal
Description
U
U
Motor connection phase U
V
V
Motor connection phase V
W
W
Motor connection phase W
A
Reserved
Do not connect
26870460/EN – 05/2021