Manual – XFE24A EtherCAT Fieldbus Interface
5
Configuring the EtherCAT master for MOVIAXIS® using the XML file
EtherCAT Configuration and Startup
Static PDO for 16
cyclical process
data words
The process output data transferred with
OutputData1
are permanently assigned ac-
cording to the following table. The process output data PO1 ... PO16 can be linked to
different process data (control words, setpoints) via the PDO Editor in the MOVIAXIS
®
multi-axis servo inverter (
→
"MOVIAXIS
®
Multi-Axis Servo Inverter" project planning
manual).
Assignment of the
permanently con-
figured process
output data for
PDO OutputData1
61992AXX
Figure 5: Assignment of standard process output data for OutputData1
PO 1
PO 2
PO 3
PO 4
PO 5
PO12
PO13 PO14
PO15 PO 16
acycl. Mailbox
Communication
cycl. OutputData1
(Standard 16 PO)
...
Index.Subindex
Offset in the PDO
Name
Data type
Size in bytes
3DB8.0hex
(15800.0dez)
0.0
PO1
UINT
2
3DB9.0hex
(15801.0dez)
2.0
PO2
UINT
3DBA.0hex
(15802.0dez)
4.0
PO3
UINT
3DBB.0hex
(15803.0dez)
6.0
PO4
UINT
3DBC.0hex
(15804.0dez)
8.0
PO5
UINT
3DBD.0hex
(15805.0dez)
10.0
PO6
UINT
3DBE.0hex
(15806.0dez)
12.0
PO7
UINT
3DBF.0hex
(15807.0dez)
14.0
PO8
UINT
3DC0.0hex
(15808.0dez)
16.0
PO9
UINT
3DC1.0hex
(15809.0dez)
18.0
PO10
UINT
3DC2.0hex
(15810.0dez)
20.0
PO11
UINT
3DC3.0hex
(15811.0dez)
22.0
PO12
UINT
3DC4.0hex
(15812.0dez)
24.0
PO13
UINT
3DC5.0hex
(15813.0dez)
26.0
PO14
UINT
3DC6.0hex
(15814.0dez)
28.0
PO15
UINT
3DC7.0hex
(15815.0dez)
30.0
PO16
UINT