Chapter 3:
Device
connectivity
33
v3.3-a 12/07/2022
Chapter 3:
Device connectivity
3.1 Default configuration
The ZEN family devices are factory configured with the following default settings:
Port/service
Default value
eth0
Waits for DHCP offer
eth1
192.168.77.100
Timing Preset
•
Slave on WR0 (BC)
•
WR master on all other ports
HTTPS
Disabled
SSH/web credentials
•
User: root
•
Password: root
Table 3:1 - Default factory settings
The devices' credentials can be configured as needed. Learn more in the Security and
Authentication section (§Chapter 6:).
3.2 Necessary items for connectivity
These are the required cables and adapters:
●
RJ-45 Cat5/6/7 Ethernet cable.
●
RJ45-RS232(m) and RS232(f)-USB cable.
3.3 Connecting to the device
There are two ways to connect to the WR-ZEN device using the terminal:
●
Via UART
●
Via SSH
This section will first introduce the general concepts on how to log to the device and then it will
provide the specific steps depending on the user OS.