PARTS IDENTIFICATION 

IMPORTANT! BEFORE FIRST USE:  
The grab handle/vacuum hose guide (see Fig. A) is shipped inside the filter basket (Fig. D). Remove the hose 
guide from the basket and install it as shown using the four screws provided. Do not overtighten the screws. The 
unit is now ready to be set up as an extractor or booster. Two Velcro straps are also enclosed in the filter basket 
(Fig. D). Use these straps to secure the extractor hose when not in use. 

 

 

 

 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 

 

 

Vacuum inlet

 (from 

extraction tool).  

Gravity drain hose

Keep capped and clipped 
into place when not in 
use.   

Grab handle/vacuum 
hose guide

. Direct hose 

through guide before use 
to avoid tipping. See 
“Before First Use” 
below for installation 
instructions. 

Filter basket cover 
latches

. Remove cover 

by lifting latches.  

Cover assembly 
latches

 (×4)  

FIG. A: FRONT

 

Also included: 

25 ft. 

section of 2 in. vacuum 
hose.  

FIG. C: CONTROL PANEL DETAIL  

P: Automatic pumpout switch.

 Turn on to activate automatic pumpout 

system. 

NOTICE!

 When automatic pumpout system is activated, sump 

pump can turn on any time liquid is present in tank. Liquid may eject from 
Pump Outlet with considerable force and cause injury. Always attach a drain 
hose and place the end in a suitable drain before activating automatic 
pumpout system.  

A: Power cord socket.

 Provides power to sump pump and blower 1.  

 

B: Power cord socket:

 Provides power to blower 2.  

 

IMPORTANT! Secure power cords into sockets with lock. 

1, 2: Vacuum blower switches.  

LOW: 

Blower 1 ON, Blower 2 OFF. Cord A required.  

MEDIUM:  Blower 1 OFF, Blower 2 ON. Cord B required.  
HIGH: 

Blower 1 ON, Blower 2 ON. Cords A and B required.  

Independent circuit indicator light:

 Glows bright green when the two cords 

are properly connected to separate circuits. No light appears if a) the two cords 
are connected to the same circuit or b) if only one cord is connected. When using 
both power cords, do not operate the unit unless the green light is illuminated.  

Power cord lock.

 Secures 

plugs in sockets.  

Automatic 

pumpout drain 

outlet

. Pre-fitted with a 1½ 

in. outlet. To use a garden 
hose, replace with the 
supplied ¾ in. fitting (inset). 
Keep capped when not in use.  

Vacuum outlet.

 Connect 

to truckmount for use as 
booster. Keep capped 
when not in use.  

Handle 

Control panel

 and 

power cord sockets

Details in Fig. C.  

Power cord retention 
clips

. Secure cord(s) here 

while using the unit. 

HEPA exhaust filter grill

Thumbscrews allows easy 
filter replacement.  

FIG. B: REAR

 

SP004 HVE3000 

Dri-Eaz Products, Inc.  

Summary of Contents for 633-115V

Page 1: ...RE HAZARD Keep away from open flames and heat sources Do not use or store where vapors from gasoline solvents thinners or other flammable materials may be present WARNING Unplug unit before cleaning o...

Page 2: ...pairs The SERVPRO RMA Department is here to serve you INTRODUCTION Some assembly required See Before first use p 3 The HVE3000 is a portable flood pumper intended for commercial use It can be teamed w...

Page 3: ...d cause injury Always attach a drain hose and place the end in a suitable drain before activating automatic pumpout system A Power cord socket Provides power to sump pump and blower 1 B Power cord soc...

Page 4: ...t outlet capped when not in use EXTRACTION OPERATION TIP Place the HVE3000 as close as possible to the end of the hose run nearest the wand or other extraction tool This position will maximize the vac...

Page 5: ...blowers emit a high pitched whine and there is no vacuum generated it most likely means that the ball float has engaged and that the tank is full and needs to be emptied or that excessive foam is pre...

Page 6: ...ing maintenance based on hours of use In excessively dusty or dirty conditions it may be necessary to perform these tasks more frequently Blower Motor Replacement 1000 hrs Order the motor brush replac...

Page 7: ...ing the assembly and cleaning it every time you inspect and clean the pump If you are servicing the float ball assembly use a Philips screwdriver to remove the float ball housing retaining screw and r...

Page 8: ...Check float and float shaft and float switch arm for smooth operation Clean as necessary Fold up the pump handle and lift out the pump for inspection Rest the pump on a table or other stable surface p...

Page 9: ...ower cord back through cord grip and retighten cord grip The cord should be slack but should not hang down and interfere with the operation of the float or the float arm assembly Reinstall the float b...

Page 10: ...22 2 No 243 Conforms to UL Std 1017 Maximum performance ratings Blower 1 low blower 8 in Hg 108 in H2O Blower 2 high blower 10 in Hg 136 in H2O Both blowers 12 in Hg 164 in H2O Pumpout discharge rate...