background image

GENERAL SERVICE, REPAIR, 

OR RETURNS

Before sending any item to Server Products for service, 

repair, or return, contact Server Products customer 

service to request a 

Return Authorization Number. 

Merchandise must be sent to Server Products with this 

number.

Merchandise being returned for credit must be in new 

and unused condition and not more than 90 days old 

and will be subject to a 20% (percent) restocking 

charge. Electrical parts (thermostats, heating elements 

etc.) are not returnable. 

Server Products maintains a fully staffed service depart-

ment with highly skilled factory trained personnel. 

Service is extremely prompt. Under normal circum-

stances, a repaired unit is shipped out the day after it is 

received. Labor charges are reasonable. 

SERVICE

Contact your dealer or Server Products Inc.  

customer service department for the following:

ORDERING REPLACEMENT PARTS  

Be prepared to give this information: 

• 

Model Letters/Name/Numbers

• 

Part Numbers- P/N

• 

Series Numbers/Letters

• 

Part Description

This information and other important data is stamped 

on the lid or cylinder of pumps or on the bottom or 
back side of every unit.

SERVER PRODUCTS 

LIMITED WARRANTY

All Server Products equipment is backed by a  

two-year limited warranty against defects in materials 

and workmanship. For complete warranty information 

go to: 

www.server-products.com

 

Server Products Inc.

 

 3601 Pleasant Hill Road

 

 Richfield, WI  53076  USA

 

262.628.5600 

 

800.558.8722

 

262.628.5110

 

[email protected]

 

www.server-products.com

 

NSF International listed.

UNIT CLEANING 

BEFORE FIRST USE AND AFTER USE DAILY,  

DISASSEMBLE AND CLEAN UNIT AND PUMP. STAINLESS 

STEEL PARTS CAN CORRODE. IT IS IMPORTANT TO  

CLEAN, RINSE, SANITIZE, AND DRY THESE PARTS DAILY 

AND PROPERLY. FAILURE TO COMPLY WITH ANY OF  

THESE INSTRUCTIONS MAY VOID UNIT WARRANTY.

SEE UNIT TAKE DOWN, PUMP DISASSEMBLY, AND 

PUMP CLEANING.

ENSURE UNIT IS “OFF” AND UNPLUGGED.

  C

   

E

Warning- Electrical shock could occur:

• 

Electrical components of unit could be 

damaged from water exposure or any liquid.

• 

Never immerse unit into water or any liquid.

• 

Never use any water jet or pressure sprayer 

on unit.

WASH PRODUCT VESSEL AND PUMP WITH 

DISHWASHING DETERGENT AND HOT WATER DAILY. 

RINSE THOROUGHLY AND DRY WITH A CLEAN SOFT 

CLOTH. 

• 

A general purpose, nonabrasive cleaner may be  

used on hard to remove food deposits.

• 

A mildly abrasive NYLON or brass brush may be 

used to remove any stubborn food or mineral 

depositson interior surfaces of unit.

• 

Do not use abrasive cleansers, scrapers,  

steel pads, steel wool, or other cleaning tools  

that can scratch surfaces.

• 

Do not use cleansing agents with high  

concentrations of acid, alkaline or chlorine.  

These agents can corrode stainless steel.

• 

Fully rinsing all parts can help prevent corrosion.

• 

Various elements and minerals, such as chlorides  

in tap water, can accumulate on stainless steel  

parts and create corrosion. 

• 

To prevent corrosion on any stainless steel parts, 

it is important to fully dry with a clean soft cloth 

regularly.

WIPE EXTERNAL SURFACES OF UNIT DAILY WITH 

A CLEAN DAMP CLOTH. DRY WITH A CLEAN SOFT 

CLOTH.

• 

A nontoxic glass cleaner may be used for cleaning 

any stainless steel parts.

SANITIZE ALL PARTS FOLLOWING LOCAL 

SANITIZATION REQUIREMENTS. ALL PARTS IN 

CONTACT WITH FOOD MUST BE SANITIZED.

• 

Allow parts to fully air dry after sanitization.

• 

Fully air drying all parts will prevent condensation 

from developing between food vessel and unit 

basin.

 

Plastic Lid, Plastic Cover, Plastic Top and  

Plastic Chiller Block Insulation Assembly:

• 

Not dishwasher safe.

• 

Hand Wash Only.

Do not place plastic lid, plastic cover, plastic top or plastic 

chiller block insulation assembly under, in, or near to high 

heat, as this can melt the plastic.

Summary of Contents for CSP

Page 1: ...eries 12G 94144 PUMP CSP 1 OZ Series 12G 94040 EZ CREAM 5 16 OUNCE 120V Series 13E 94160 PUMP CSP 5 16 OZ EZ CREAM Series 13E 94150 CSP CHILLED SERVER WITH PUMP 2 OUNCE 120V Series 12G 94050 230V Continental Europe Series 12G 94145 230V Australia Series 12G 94146 230V United Kingdom Series 12G 94147 PUMP CSP 2 OZ Series 12G 94140 01672 RevE_102813_ENGLISH ...

Page 2: ...d by sauerkraut or Aus Jus Do not place plastic lid plastic cover plastic top or plastic chiller block insulation assembly under in or near to high heat as this can melt the plastic UNIT SET UP ALWAYS CLEAN UNIT THOROUGHLY BEFORE EACH USE SEE UNIT TAKE DOWN SAFETY GUIDELINES AND UNIT CLEANING SEE SEPARATE PUMP MANUAL FOR PUMP INSTRUCTIONS 1 PLUG CORD INTO POWER SOURCE Verify that cord is securely ...

Page 3: ... dishwashing detergent Fully rinse 6 IF NECESSARY WIPE DOWN FAN COVER AND SURROUNDING AREA ON UNDERSIDE OF UNIT WITH CLOTH DAMPENED WITH DISHWASHING LIQUID OR MILD SANITIZING DETERGENT C EWarning Electrical shock could occur Be sure to wring out any excess water from cloth before wiping near fan of unit Dripping water into unit can cause electrical damage to unit 7 PLACE NEW OR CLEANED FILTER OVER...

Page 4: ...RING FROM DISCHARGE TUBE Be careful not to damage o ring when prying it off of discharge tube 8 REMOVE KNOB FROM PLUNGER ASSEMBLY BY ROTATING COUNTERCLOCKWISE Firmly hold head tube towards piston head while unscrewing knob Pressure on spring will release and push knob off rapidly 9 REMOVE LOCKING COLLAR FROM HEAD TUBE Remove gaging collar s if used from head tube by sliding them off J REMOVE HEAD ...

Page 5: ...e on stainless steel parts and create corrosion To prevent corrosion on any stainless steel parts it is important to fully dry with a clean soft cloth regularly 5 SANITIZE PARTS FOLLOWING YOUR LOCAL SANITIZATION REQUIREMENTS ALL PARTS IN CONTACT WITH FOOD MUST BE SANITIZED Allow parts to fully air dry after sanitization Dishwasher safe CLEAN IN PLACE PROCEDURE FOR PUMPS CLEAN IN PLACE IS A BASIC F...

Page 6: ...LOCKWISE TO SECURE TO THREADS OF DISCHARGE TUBE Do not use any sharp tools for assembly this can damage parts b a c VALVE COVER ASSEMBLY PUMP TROUBLESHOOTING PROBLEMS WITH PUMP OPERATION AND OR FLOW Clean pump PUMP DISPENSES LITTLE OR NO PRODUCT Product may be too stiff or contain a solid that will not pass through pump PORTION CONTROL IS NOT CONSISTENT Inspect gaging collar for any damage and or ...

Page 7: ...D END OF PISTON Firmly hold head tube towards piston head compressing spring while screwing knob on INSTALL O RINGS AND ASSEMBLE PUMP BODY 9 INSTALL SMALL O RING ONTO DISCHARGE TUBE Apply food equipment lubricant on o ring Be careful not to damage o ring while installing and or rolling onto discharge tube J INSTALL SILICONE GASKET OR O RING INTO VALVE BODY Apply food equipment lubricant on silicon...

Page 8: ...TH ANY OF THESE INSTRUCTIONS MAY VOID UNIT WARRANTY 1 SEE UNIT TAKE DOWN PUMP DISASSEMBLY AND PUMP CLEANING 2 ENSURE UNIT IS OFF AND UNPLUGGED C EWarning Electrical shock could occur Electrical components of unit could be damaged from water exposure or any liquid Never immerse unit into water or any liquid Never use any water jet or pressure sprayer on unit 3 WASH PRODUCT VESSEL AND PUMP WITH DISH...