background image

SLPAC10

Portable Air Conditioner

Fan and Dehumidifier

Summary of Contents for SLPAC10

Page 1: ...SLPAC10 Portable Air Conditioner Fan and Dehumidifier ...

Page 2: ...nents 4 Control Panel and Remote Controller 6 Product Operation Placement and Installation 7 Operation Method 9 Clean and Maintenance Drainage Method 10 Maintenance 11 Common Failures and Diagnosis Intelligent Error Detection 12 Fuse Parameters 12 Troubleshooting 13 www SereneLifeHome com ...

Page 3: ...f the A C should meet requirements Any damage incurred by incorrect power isn t included in the warranty Children are not allowed to play with the A C This appliance is not intended for use by children unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Don t insert your fingers or any hard object to wind guide bar of the ...

Page 4: ...eform and electric parts may be damaged Power The plug should be in good condition and can t be damaged Don t replace the plug with power plug In order to run the A C plug the power cord first and then press the power key Place unit in upright position for 2 hours before turning on for first time Product Introduction MAIN PARTS AND COMPONENTS 1 Handle 2 Air inlet L 3 Control panel 4 Wind guide ven...

Page 5: ...5 1 2 3 4 5 6 7 8 9 10 11 12 www SereneLifeHome com ...

Page 6: ...t timing ON OFF time press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature 5 Mode key Press the key to choose cooling fan dehumidification 6 Timer key Press the key at standby mode to set ON time Press this key at ON mode to set OFF time 7 Temperature Time Display Window This window displays the adjusted temperature and time 8 Remote controller receiving wind...

Page 7: ...d Installation Placement Place it at even and dry place and keep it at least 50cm away from its surrounding object Installation Screw the exhaust duct assembly in the air outlet behind the panel counterclockwise www SereneLifeHome com ...

Page 8: ...important to keep the exhaust duct smooth Incorrect installation will affect work of the A C Prevent the exhaust duct from sharp bending Ensure air can flow smoothly in the duct Warning The exhaust duct is designed especially for this model Don t replace or lengthen it otherwise it will result in failure Notice Max developed length of the exhaust duct is 1 500mm It s better to shorten it while use...

Page 9: ...on mode by pressing the remote controller the dehumidification indicator lamp lights up Remove the dehumidification water wedge insert water manifold place the other end of the water manifold into the water vessel or drainage passage as shown in the right figure After entering the dehumidification mode if room tempearture 17 C 62 F the compressor is ON Then control as follows when room temperature...

Page 10: ... Press Up and Down keys to set ON time 1 24H and the timer indicator lamp lights up In ON state pressure the timer key to set OFF time Press Up and Down keys to set OFF time 1 24H and the timer indicator lamp lights up Clean and Maintenance DRAINAGE METHOD This product is equipped with automatic water vaporization system The condenser is cooled with the circulating of condensing water so as to imp...

Page 11: ...ill be damaged Prevent water from spattering in the A C FILTER SCREEN Vacuum the filter screen once every two weeks If it is blocked by dust efficiency of the A C will be reduced Take out the air inlet grille and pull out the filter screen at both sides according to the direction shown in the following figures Use vacuum to remove lint from filters Put the filter screen into the warm water about 4...

Page 12: ...a plastic bag and place it at a dry place Common Failures and Diagnosis Intelligent Error Detection FUSE PARAMETERS Voltage 250VAC Current 3 15A Error detecting code Multi functional defection E1 Error of the coil s temperature sensor E2 Error of indoor temperature sensor E4 Anti freezing protection temperature of the coil is too low and the whole A C is off When temperature excesses 8 C or 46 4 F...

Page 13: ...rs and windows remove heat source Filter screen is very dirty Clean orreplace it Air inlet orair outlet is blocked Remove the stem Big noise of the A C TheA Cis placed unevenly Place it at even and firm ground avoid shaking Thecompressor doesn t work Its delay protection is started Wait for 3min turn on after temperature decreases TROUBLE CAUSE SOLUTION Do not dispose of electrical appliances as u...

Page 14: ......