Data Pro
P/N 10029355 Rev AE
Operation Manual
Page 47 of 92
Figure 42
– ESP Gauge Channel Streaming Configuration
Figure 43
– ESP Gauge Channel Configuration Upload Message
The streaming mode
, available only on ‘U-Command’ gauges, sets the faster sampling time for the
‘
High Speed
Enabled’
channels and their sampling rate is reflected in the ‘
Rate (Sec.)
’ column on the
‘Ch. Config’
screen. The ‘
High Speed
Enabled’
channel is represented by
‘+’
sign next to parameter
name on the front screen gauge data grid. After changes, new gauge log files are created based on the
updated enabled/disabled channel. Data will then record at sample rate set by:
Menu
System
Sample Rate
In order to record the
‘high speed’ channel data, the user must change the sample rate of the Data Pro
to match the
‘
Rate (Sec.)
’ time,