Solenoid diaphragm pump
Series R/RS 204.1
Operating Instructions
TA 416
Rev.
11 en
04/2013
Subject to technical modifications!
www.sera-web.com
19
7.2.2
Pump body
Depending on the applied backpressure, movements of the
plastic pump body in elastic materials are possible.
This doe
s not affect the pumps’s service life or operational re-
liability.
7.2.3
Manual vent valve (only FRP-
execution R 204.1-1,2e - ...-14e, RS
204.1-6,0 -
…-14e)
Function
The vent valve is used to release the manual pressure in the
pump body during commissioning. Open vent valve when
pump primes first time.
When vent valve is opened gas including medium escapes into
the feedback line. The vent valve must be closed again as
soon as only medium without gas constituent escapes. The
pump now feeds the medium into the pressure line.
Open again for another ventilation. The vent valve consists of
a vent screw with integrated hose nozzle, which must be fitted
with a hose (inside diameter 6 mm) as feedback line (see Fig.
11). The leaking medium incl. the gas admixtures must be dis-
posed off properly
Vent screw
Integrated hose nozzle
Hose
Pump body
Fig. 11 Vent valve
The vent screw is inserted during normal operation.
CAUTION!
Open vent screw with great caution and perform max. 1
turn. Take care that the tightness of the thread is still
guaranteed.
ACHTUNG !
The vent screw must always be closed during the driving
process.
7.2.4
Electronics (with control panel)
The electronics enable, among others, the proportional dosing
via analog signals 4
… 20mA.
The three LEDs serve for indicating warning signals, errors
and the current status of the dosing pump (see Fig. 12).
An indicator “empty” along with pre-alarm and dry run indica-
tors is installed as standard.
LED- display
Fig. 12 Electronics