4 SBF Reference
4.2.9
SBAS L1 Decoded Message Blocks
GEOMT00
Number:
5925
"OnChange"
interval: block generated each time an empty MT00 is received
from an SBAS satellite on the L1 signal
This block is sent to indicate that an empty SBAS message type 0 has been received.
Depending on the SBAS operational mode, message type 0 can contain the contents
of message type 2. Upon reception of a message type 0, the receiver checks whether the
message is empty (it contains only 0’s) or whether it contains the message type 2 contents. In
the former case, a
GEOMT00
block will be generated. In the latter case, a
block
will be generated. Refer to section A.4.4.1 of the DO 229 standard for further details.
Parameter
Type Units
Do-Not-Use
Description
Sync1
c1
Block Header, see 4.1.1
Sync2
c1
u2
ID
u2
Length
u2
1
byte
u4
0.001
s
4294967295
u2
1
week
65535
u1
ID of the SBAS satellite from which the message has been received (see
Padding
u1[..]
Padding bytes, see 4.1.5
367