1 How To...
1.5
Save the Configuration in Non-Volatile
Memory
The receiver configuration includes all the user-selectable parameters, such as the elevation
mask, the PVT mode, the COM port settings,...
By default, the receiver starts up in its factory default configuration. The factory defaults
for each of the receiver parameters are underlined for each argument of each command in
section 3.2
The current receiver configuration can be checked with the
command:
At any time, it is possible to save the current configuration into non-volatile memory, in order
to force the receiver to always start up in that configuration. To do so, the following command
should be entered:
exeCopyConfigFile,Current,Boot <CR>
To revert to the default setting where the receiver starts in the default configuration, you
should use:
exeCopyConfigFile,RxDefault,Boot <CR>