3 Command Line Reference
sncu
gncu
setNtripCasterUsers
getNtripCasterUsers
UserID
UserID
UserName (20)
Password (40)
MountPoints
MaxClients
+ User1
+ User2
+ User3
+ User4
+ User5
all
none
+ MP1
+ MP2
+ MP3
all
1 . . . 10
RxControl: Communication > NTRIP Settings > NTRIP Caster settings
This command defines the user accounts (user name and password) that clients can use
to connect to the built-in NTRIP caster. The password must contain at least one character
(empty passwords are not supported). Up to five user accounts can be defined.
The
MounPoints
argument defines the list of mount points allowed for a given user account.
The caster can accept up to 10 concurrent client connections in total. The
MaxClients
argu-
ment can be used to limit the number of clients that are allowed to concurrently connect
using a particular account.
To delete a user account, enter this command with an empty
UserName
argument.
Note that the caster is reset each time a user account is added, deleted or modified with this
command.
Example
COM1>
sncu, User1, MyUser, MyPwd, all, 1<CR>
$R: sncu, User1, MyUser, MyPwd, all, 1
NtripCasterUsers, User1, MyUser, MyPwd, all, 1
COM1>
199
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...