3 Command Line Reference
3.2.12
General Input/Output
scs
gcs
setCOMSettings
getCOMSettings
Cd
Cd
Rate
DataBits
Parity
StopBits
FlowControl
+ COM1
+ COM2
+ COM3
+ COM4
all
baud1200
baud2400
baud4800
baud9600
baud19200
baud38400
baud57600
baud115200
baud230400
bits8
No
bit1
none
RTS|CTS
RxControl: Communication > COM Port Settings
Use these commands to define/inquire the communication settings of the receiver’s COM
ports. By default, all COM ports are set to a baud rate of 115200 baud, using 8 data-bits, no
parity, 1 stop-bit and no flow control.
Depending on your receiver hardware, it may be that not all COM ports support flow control.
Please refer to the receiver Hardware Manual or User Manual to check which COM ports are
equipped with the RTS/CTS lines.
When modifying the settings of the current connection, make sure to also modify the settings
of your terminal emulation program accordingly.
Example
COM1>
scs, COM1, baud19200, bits8, No, bit1, RTS|CTS<CR>
$R: scs, COM1, baud19200, bits8, No, bit1, RTS|CTS
COMSettings, COM1, baud19200, bits8, No, bit1, RTS|CTS
COM1>
178
Summary of Contents for PolaRx5TR
Page 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Page 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Page 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Page 237: ...3 Command Line Reference COM1 237 ...
Page 279: ...3 Command Line Reference COM1 279 ...
Page 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...