3 Command Line Reference
spin
gpin
setPPSINParameters
getPPSINParameters
XOCompensation
off
auto
RxControl: Navigation > Receiver Operation > Timing
Use this command to enable or disable automatic compensation of the delay between the
PPS IN pulse at the PPS IN connector and the receiver internal time reference. This delay is
commonly referred to as X
O
in the literature.
When delay compensation is enabled (the
XOCompensation
argument is set to
auto
), X
O
can
be considered zero in all time transfer applications.
When delay compensation is disabled, X
O
is not zero and must be measured by external
means.
Refer to the User Manual for more details on the usage of the PPS IN input signal.
Example
COM1>
spin, off<CR>
$R: spin, off
PPSINParameters, off
COM1>