3 Command Line Reference
scgt
gcgt
setCGGTTSTrackParameters
getCGGTTSTrackParameters
ElMask
TrackSchedule
-90 . . . 10 . . . 90
deg
BIPM
Contiguous
RxControl: Logging > Internal CGGTTS Logging > CGGTTS Parameters
This command configures some parameters of the CGGTTS computation.
The
ElMask
argument specifies the elevation mask to be used when computing the CGGTTS
data. This mask is only used in the context of CGGTTS. The global receiver elevation mask is
set with the
command.
The scheduling of the 13-minute CGGTTS tracks is defined with the
TrackSchedule
argument.
By default, the conventional BIPM scheduling is applied (13-minute tracks starting at pre-
defined epochs with 3-minute idle intervals between tracks). In
Contiguous
mode, the
CGGTTS parameters are computed every 13 minutes without idle interval, starting directly
when CGGTTS logging is enabled. This non-standard mode provides a faster update rate of
the time-transfer parameters.
Example
COM1>
scgt, 15, BIPM<CR>
$R: scgt, 15, BIPM
CGGTTSTrackParameters, 15, BIPM
COM1>
169