3 Command Line Reference
sbbs
gbbs
setBBSamplingMode
getBBSamplingMode
Mode
BeforeIM
AfterIM
RxControl: Navigation > Advanced User Settings > Frontend and Interference Mitigation > Frontend Settings
Use this command to configure the baseband samples (ADC samples) logged in the
SBF block.
The following sampling modes are defined:
Mode
Description
BeforeIM
The samples in the
SBF block are taken before inter-
ference mitigation (see the
command).
All frequency bands are sampled in turn.
AfterIM
The samples in the
SBF block are taken after inter-
ference mitigation (see the
command).
All frequency bands are sampled in turn.
Example
COM1>
sbbs, BeforeIM <CR>
$R: sbbs, BeforeIM
BBSamplingMode, BeforeIM
COM1>
120