Ratings 

POWER RATINGS 

INDICE D’ALIMENTATION 

 

NENNLEISTUNG 

PTPD-V0##-y-0z* 
* ## - Number of outlets 
   y - Input Voltage (1-100-120V, 50/60Hz 
   w/NEMA outlets, 2-100-240V 60Hz & 
   230V 50/60Hz w/IEC 60320/C13 outlets)
   z - Power input configuration 

PTPD-V0##-y-0z* 
*  ## - Nombre de prises 
   y - Tension d’entrée (1-100-120V, 
  50/60Hz w/NEMA prises, 2-100-240V 
  60Hz & 230V 50/60Hz w/ IEC 
  60320/C13  prises) 
   z – Configuration de l’entrée de 
  l’alimentation  

PTPD-V0##-y-0z* 
* ## - Anzahl der Anschlussstellen 
   y - Eingangsspannung (1 - 100-120V, 
  50/60Hz mit NEMA-Anschlussstellen, 2 - 
  100-240V, 60Hz, und 230V, 50/60Hz mit 
  IEC 60320/C13-Anschlussstellen) 
   z - Eingangskonfiguration 

Outlets

Voltage

Current

Outlet

Total

Prises

Tension

Courrant

Prise

Sextet

5

Total

Anschlussstellen

Spannung

Strom

Anschlussstelle

A

B

C

D

A&B

C&D

Insgesamt

08

100-120V 50/60Hz

15

10

15

15

15

15

08

100-120V 50/60Hz

20

10

15

15

20

20

08

100-120V 50/60Hz

30

10

15

15

30

30

16

100-120V 50/60Hz

15

10

15

15

15

15

15

15

15

16

100-120V 50/60Hz

20

10

15

15

15

15

15

15

20

16

100-120V 50/60Hz

30

10

15

15

15

15

15

15

30

18

100-120V 50/60Hz

15

10

10

15

18

100-120V 50/60Hz

20

10

10

20

18

100-120V 50/60Hz

30

10

10

30

08

208-240V 60Hz

20

6

10

10

20

20

08

208-240V 60Hz

30

6

15

15

30

30

16

208-240V 60Hz

20

6

10

10

10

10

20

20

20

16

208-240V 60Hz

30

6

15

15

15

15

24

24

30

18

208-240V 60Hz

20

6

10

20

18

208-240V 60Hz

30

6

10

30

08

230V 50/60Hz

16

6

10

10

16

16

08

230V 50/60Hz

30

6

15

15

30

30

16

230V 50/60Hz

16

6

10

10

10

10

16

16

16

16

230V 50/60Hz

30

6

15

15

15

15

24

24

30

18

230V 50/60Hz

16

6

10

16

18

230V 50/60Hz

30

6

10

30

3

 A=A1+A2+A3+A4 or 1+2+3+4, B=B1+B2+B3+B4 or 5+6+7+8, C=C1+C2+C3+C4 or 9+10+11+12, D=D1+D2+D3+D4 or 13+14+15+16

4

 A&B=A1+A2+A3+A4+B1+B2+B3+B4 or 1+2+3+4+5+6+7+8, C&D=C1+C2+C3+C4+D1+D2+D3+D4 or 9+10+11+12+13+14+15+16

5

 1+2+3+4+5+6 OR 7+8+9+10+11+12 OR 13+14+15+16+17+18

Les configurations suivantes NE SONT PAS disponible:
   Unités de 100-120V avec indice de courant d’entrée de 16A.
   Unités de 208-240V et 230V avec indice de courant d’entrée de 15A.

Die folgenden Konfigurationen sind NICHT verfügbar:
   100-120V-Einheiten mit einer Eingangsstromstärke von 16A
   208-240V und 230V-Einheiten mit einer Eingangsstromstärke von 15A

Available Configurations 

Configurations Disponibles 

Verfügbare Konfigurationen

6

Input Current Ratings

1,2

Output Current Ratings

L’indice du courant d’entrée

L’indice du courant de sortie

Eingangsstromstärke

Ausgangsstromstärke

Quad

3

Octet

4

All current ratings are in amperes.

  

Tous les indices de courant sont en ampères.

  Alle Angaben der Stromstärke erfolgen in Ampere.

2

 

Input current ratings are based on the power input configuration.

 

Les indices du courant d’entrée sont basés sur la configuration de tension d’entrée.

 

Die Eingangsstromstärke hängt von der Eingangskonfiguration ab.

The following configurations are NOT available:

   100-120V units with 16A input current rating.
   208-240V and 230V units with 15A input current rating.

Physical Specifications 

Model 

PTPD- 

Vx08 Vx16 Vx18 Hx08 Hx16 

Size (H, W, D):  ‘0’ series 
  

‘E’ 

series 

43.0 x 1.75 x 2.25 in 

N/A 

65.0 x 1.75 x 2.25 in 

63.0 x 2.0 x 1.75 in 

N/A 

62.0 x 2.0 x 1.75 in 

1.75 x 17.25 x 5.5 in 

N/A 

33.0 x 1.75 x 2.25 in 

N/A 

Weight: 

8.0 lb 

10.9 lb 

10.6 lb 

7.0 lb 

7.8 lb 

Temperature: Operating 
  

Storage 

0

°

 to 50

°

 C (32

°

 to 122

°

 F) 

-40

°

 to 85

°

 C (-40

°

 to 185

°

 F) 

Elevation: Operating 
(above MSL): 

Storage 

0 to 10,000 ft (0 to 3000 m) 

0 to 50,000 ft (0 to 15 000 m) 

Rel. humidity: 

Operating 

  

Storage 

10 to 90%, non-condensing 

10 to 90%, non-condensing 

Approvals cTUVus, 

TUV-GS

1

 

cTUVus - UL 60950:2000, CAN/CSA 22.2 No. 60950-00,  TUV-GS - EN60950:2000 

Sentry Power Tower Power Distribution Unit 

Appendices 

 

17

 

Installation and Operations Manual 

 

Technical Specifications 

 

Summary of Contents for PTPD-H0

Page 1: ...Sentry AC Power Distribution Unit PTPD V0 PTPD H0 PTPD VE PTPD HE Installation and Operations Manual...

Page 2: ...alysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for adults or infants anesthesia ventilators infusion pumps and any other devices designated as critical by the U...

Page 3: ...Mounting 6 Connecting to the Power Source 6 Connecting Devices to the PTPD 7 Connecting to the PTPD PTPD x0 models only 7 CHAPTER 3 OPERATIONS PTPD X0 MODELS ONLY 9 Interface 10 Displaying the Contro...

Page 4: ......

Page 5: ...Chapter 1 Introduction FEATURES AND BENEFITS 2 Power Distribution 2 Load Measurement 2 Over Threshold Notification 2 Technical Support 2 QUICK START GUIDE 2...

Page 6: ...PD xE models Over Threshold Notification Sentry Power Distribution Units features two standard over threshold alarms an audible alarm for the local technician and a contact closure alarm circuit which...

Page 7: ...ITEMS 4 EQUIPMENT OVERVIEW 4 SAFETY PRECAUTIONS 5 VERIFY INPUT VOLTAGE SELECTION PTPD VE18 MODELS ONLY 5 MOUNTING 6 Horizontal Rack PTPD 6 Vertical PTPD 6 CONNECTING TO THE POWER SOURCE 6 CONNECTING D...

Page 8: ...ough A4 B1 through B4 C1 through C4 and D1through D4 The power inlet of the PTPD connects the PTPD to the electrical power source See Appendix C Technical Specifications for more information Ports Inp...

Page 9: ...wer supply cord shall be installed near the equipment and shall be easily accessible La prise sur le cordon d alimentation sera install e pr s de l quipement et sera facilement disponible Der Stecker...

Page 10: ...es Representative for information regarding custom bracket design and fabrication services if you are unable to find a suitable manner for utilizing the included mounting brackets Connecting to the Po...

Page 11: ...esigned for use with Server Technology s IEC 60320 C13 to IEC 60320 C14 cable CAB 1302 The retention clip may not properly fit 3rd party cables Always disconnect the power supply cord before opening t...

Page 12: ......

Page 13: ...reen 10 USING THE CONTROL SCREEN 10 Location field 10 To specify a location 10 Input Current field 10 Threshold field 10 To adjust the overload threshold 10 Alarm Status field 11 Clearing an Over Thre...

Page 14: ...ocation field T Pressing T allows editing of the overload threshold Enter Displays or refreshes the Control Screen The following sections describe each Control Screen field Location field The editable...

Page 15: ...rrent returns to 1 8 ampere below the overload threshold To clear an alarm from the Control Screen Type c To clear an alarm using the reset button On the front of the PTPD locate the recessed reset bu...

Page 16: ......

Page 17: ...TIONAL VOLTAGE 15 APPENDIX C TECHNICAL SPECIFICATIONS 16 Standard Models 16 Ratings 17 Fuses 17 Data Connection PTPD x0 models only 18 RJ45 to DB9F serial port adapter 18 IDC10 alarm port 19 APPENDIX...

Page 18: ...eset button directly below the Input Current LED You will need a non conductive non metallic tool that fits inside the recess Insert the tool in the recess then depress and hold the reset button for a...

Page 19: ...crews from access plate on the back of the Sentry Power Distribution Unit 2 2 Remove the access plate 3 Verify the proper setting on the voltage selector switch Correct as necessary 115V for 100 120V...

Page 20: ...red NEMA 5 15P 15A 125V straight 18 IEC 60320 C13 PTPD VE18 0 04 100 240V 50 60Hz Hardwired NEMA L5 20P 20A 125V locking 18 IEC 60320 C13 PTPD VE18 0 05 100 240V 50 60Hz Hardwired NEMA L5 30P 30A 125V...

Page 21: ...D4 or 9 10 11 12 13 14 15 16 5 1 2 3 4 5 6 OR 7 8 9 10 11 12 OR 13 14 15 16 17 18 Les configurations suivantes NE SONT PAS disponible Unit s de 100 120V avec indice de courant d entr e de 16A Unit s d...

Page 22: ...an RJ45 RS 232c serial port This connector may be used for direct local access or from other serial devices such as a terminal server An RJ45 crossover cable is provided for connection to an RJ45 DTE...

Page 23: ...The relay switches to close the circuit in response to an over threshold alarm Normally Closed The relay switches to open the circuit in response to an over threshold alarm 2 Relay specifications Manu...

Page 24: ...strict compliance with Server Technology s operation and installation manual c has become defective or inoperative due to its integration or assembly with any equipment or products not supplied by Ser...

Page 25: ...irs Server Technology shall assume return shipping charges but for non warranty repairs the shipping charges shall be billed 3 The RMA shall be placed conspicuously on all shipping documentation assoc...

Page 26: ...a 89521 775 284 2000 Fax 775 284 2065 E mail sales servertech com World Wide Web www servertech com Sentry and Sentry Power Distribution Unit are trademarks of Server Technology Inc 301 0121 1 Rev C 0...

Reviews: