background image

Original Instructions

Installation, Operation 

& Maintenance Manual

Sentry CPS Sampler

Corrosion Sampler

S-SW-IOM-00252-17 12-18

Summary of Contents for CPS-10 w/ Batt

Page 1: ...Original Instructions Installation Operation Maintenance Manual Sentry CPS Sampler Corrosion Sampler S SW IOM 00252 17 12 18...

Page 2: ...ecifically disclaim all liabilities and warranties express or implied including warranties of merchantability and fitness for a particular purpose for the accuracy currency completeness and or reliabi...

Page 3: ...s DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injur...

Page 4: ...h any chemical Read the product label and Material Safety Data Sheets MSDS carefully and follow the instructions exactly Potential Equipment Hazards Hot surfaces This equipment may have very hot surfa...

Page 5: ...when referring to this manual Some of the illustrations may or may not include options which you have Model Description psig Barg F C CPS 10 w Batt Single Stream w bypass battery 2850 196 131 55 CPS 1...

Page 6: ...ing sample line velocities of 5 6 feet per second as recommended by EPRI This flow requirement is especially important given the sole purpose of CPS sampling is to measure sample constituents that can...

Page 7: ...thout leakage and without the need for tools to open and close the housing It is designed such that varying stack heights of filter papers do not interfere with the housing s sealing capabilities All...

Page 8: ...ow the operators of Corrosion Products sampler to open and close the housing for filter replacement Stacking more than three filter papers is not recommended or leakage will occur All wetted metal sur...

Page 9: ...ability Hydrophilic Qty Pkg 100 Thickness 180 m Anion Exchange Filter Sentry p n 4 05055A Usage Collection of dissolved negatively charged ions anions i e Cl Br OH Filter Diameter 47 mm Filter Surface...

Page 10: ...Compression fitting Sample Outlet Drain 3 4 O D Tube Stub SS See note below Cooling Water Inlet Outlet if installed 3 4 Compression fittings NOTE Since the liquid effluent is at atmospheric pressure t...

Page 11: ...h hex Allen wrench Because the seal is made around the housing face it is recommended to tighten the bolts using the opposite star pattern method When the filter holder is properly assembled and tight...

Page 12: ...rned fully counterclockwise the bypass flow control valve is fully closed the sample inlet valve is fully closed and the filter inlet isolation valve is fully closed Reset the totalizer reading by pre...

Page 13: ...e the valve trip point it will be necessary to hold the reset button in until cooled sample allows the valve to latch If the TSV trips during sampling operations isolate the analyzers on the line or l...

Page 14: ...sembly Do not exceed the pressure and temperature ranges for the unit Battery Maintenance For units with a battery option the battery voltage level can be checked by pressing the Battery Condition Tes...

Page 15: ...exceed 16 it is probable that damage to the sensor has occurred If values are between 4 and 16 recalibration is necessary Recalibrating Flow Meter NOTE It is necessary to document programmed values p...

Page 16: ...the steps below 8 Connect Power to the unit 9 Take unit out of calibration mode On some models using the meter calibration switch located on the CPS sampler will do this Otherwise disconnect the male...

Page 17: ...otalizer display enclosure Connect the female push on disconnect located at terminal 5 on the Flow Totalizer display to the male push on disconnect located at TB1 1 in the electrical enclosure 17 Adju...

Page 18: ...f the CPS sampler will do this Otherwise use a jumper to connect terminal 5 to terminal 4 on TB1 located in the electrical enclosure 5 Using your recorded programming values reenter these values into...

Page 19: ...r the Flow Totalizer loop and the other for the by pass loop Pressure Regulator PR 1 Little if any maintenance is required If you are unable to achieve the recommended pressure of 14 5 psig 1 bar and...

Page 20: ...Encapsulated Outer O ring 7 02065D 4 02342X 2 04061Q 4 04332A 4 02342X 5 Regulator Standard HP High Pressure Replacement Diaphragm 4 01433T 4 01433G 4 00367B 6 Pressure Gauge 4 04139J 7 Sample Flow I...

Page 21: ...isplay Battery 4 05953P 22 Power Input Fuse 10A 4 05953V 23 Battery In line Fuse 10A 4 05953X 24 TSV Thermal Shut off Valve 120 F 7 01137E 25 Relief Valve 30 psi Fixed Cracking Pressure 4 01233L NOTE...

Page 22: ...n the table below Product Line Product Category Warranty Period Sentry 1 Automatic Sampling 2 Corrosion Monitoring 3 Manual Sampling 4 Sample Conditioning 5 Sampling Analysis Systems 6 Replacement Par...

Page 23: ...itioning sampling and measuring gas liquid slurry powder solids steam or water within their production environments our customers obtain the critical insights they need to control and optimize their p...

Page 24: ...sentry equip com 966 Blue Ribbon Circle North Oconomowoc WI 53066 U S A 1 262 567 7256 support sentry equip com Serving customers in more than 50 countries across six continents worldwide...