29
8.30
8.30
8.30
8.30
8.30 MISCELLANEOUS SYSTEM FUNCTION SELECT
MISCELLANEOUS SYSTEM FUNCTION SELECT
MISCELLANEOUS SYSTEM FUNCTION SELECT
MISCELLANEOUS SYSTEM FUNCTION SELECT
MISCELLANEOUS SYSTEM FUNCTION SELECT
(1-8) - FUNCTION GROUP 3
(1-8) - FUNCTION GROUP 3
(1-8) - FUNCTION GROUP 3
(1-8) - FUNCTION GROUP 3
(1-8) - FUNCTION GROUP 3
Use the following chart to set the third system function group:
Most of the third function group selects, apply to the installation of
optional remote Data Output Boards.
Use the following chart to set the third system function select
groups.
1
Bell Module installed
(Data Output Board - DOB)
2
System status module installed
(Data Output Board - DOB)
3
Disable Exit Delay Annunciation
4
Printer output installed
(Data Output Board - DOB)
5
Timer switch output, On
(Available off of DOB or Assignable Output)
6
Keypad switched output, On
(Available off of DOB or Assignable Output)
7
Computer controlled output 1, On
(Available off of DOB or Assignable Output)
8
Computer controlled output 2, On (Available off of DOB only)
1
Set this digit to enable the Bell Module DOB
DOB
DOB
DOB
DOB. The bell module
contains the following outputs:
* Four Area Controlled burglary bell outputs. Outputs 1-4 are
assigned to keypads 1-4 respectfully.
EXAMPLE 1:
EXAMPLE 1:
EXAMPLE 1:
EXAMPLE 1:
EXAMPLE 1:
If zones 1, 2, 3 are assigned to keypad 1, then ONLY these
zones will activate bell module output 1. And if zones 5,6,7 are
assigned to keypad 3, then ONLY these zones will activate bell
module output 3.
EXAMPLE 2:
EXAMPLE 2:
EXAMPLE 2:
EXAMPLE 2:
EXAMPLE 2:
Keypad 1 was assigned zones 3,4, and 5, and user 2 was
assigned zones 3 and 4. Bell 1 was activated by zone 5, since
user 2 was not assigned zone 5 he cannot deactivate bell 1 at
keypad 1 unless Item 30 part 1 is programmed with an eight –
Silence All Area Bells.
* One Non-pulsing Fire Bell output.
* One Smoke Reset output which is active at the same time
and duration as the system smoke power output.
* One Door Strike output. To enable this output, the proper user
attribute must be selected (refer to item 67).
* One Strobe Output. Acts similar to the burglary bell output,
except that there is no auto shut off. An access code is
required to reset the strobe.
2
Select this digit to enable the System Status Module DOB
DOB
DOB
DOB
DOB. The
Status Module Contains the following outputs:
* AC Fail output.
* Switched timer output. The output time and duration of this
timer are programmed in items 31 and 32. This output could
be used to turn on an outside light, activate a sprinkler
system, or any other timer controlled function.
* Keypad activated output. This remote output is activated at
any keypad with the following key sequence:
[PPPP] [ * ] [1&2] [ 4 0 ] [ # ]. To turn o f f this output, use
the following key sequence: [PPPP] [ * ] [1&2] [ 4 1 ] [ # ]
* 2 Computer Controlled outputs, PC Output 1 and Output 2.
* Low Battery condition output.
* Fail to Communicate output.
* Zone Trouble output
3
Select this digit to disable keypad annunciation during exit
delay.
4
Select this digit to enable the printer DOB
DOB
DOB
DOB
DOB module.
5
Select this digit to enable the timer output on the system status
module or Assignable Output.
6
Select this digit to enable the keypad activated output on the
system status module or Assignable Output.
7
This digit enables the computer controlled output (1) (located
on the system status module)or Assignable Output.
8
This digit enables the computer controlled output (2) (located
on the system status module).
8.31
8.31
8.31
8.31
8.31 REMOTE CONTROL TIMER
REMOTE CONTROL TIMER
REMOTE CONTROL TIMER
REMOTE CONTROL TIMER
REMOTE CONTROL TIMER
This timer sets the time of day when the timer output (located on the
system status module) is active. Refer to item 32 for the output
duration.
8.32
8.32
8.32
8.32
8.32 REMOTE CONTROL TIMER DURATION (1-95)
REMOTE CONTROL TIMER DURATION (1-95)
REMOTE CONTROL TIMER DURATION (1-95)
REMOTE CONTROL TIMER DURATION (1-95)
REMOTE CONTROL TIMER DURATION (1-95)
Remote control window (1-95) controls how long the remote control
outputs are active (15 minute increments). At a setting of 95 the
duration is at maximum duration of 23.75 hours.
Caution:
Caution:
Caution:
Caution:
Caution: V
V
V
V
Values set in e
alues set in e
alues set in e
alues set in e
alues set in excess of 95 will cause err
xcess of 95 will cause err
xcess of 95 will cause err
xcess of 95 will cause err
xcess of 95 will cause error
or
or
or
ors.
s.
s.
s.
s.
8.33
8.33
8.33
8.33
8.33 ASSIGNABLE OUTPUT
ASSIGNABLE OUTPUT
ASSIGNABLE OUTPUT
ASSIGNABLE OUTPUT
ASSIGNABLE OUTPUT
This output may be programmed to p12.5 V.D.C at terminal
8 whenever the selected condition occurs. Program as follows:
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
PR
PR
PR
PR
PROGRAM ENTR
OGRAM ENTR
OGRAM ENTR
OGRAM ENTR
OGRAM ENTRY
Y
Y
Y
Y
0
Burglar Bell
6
Ready/Trouble
1
Arm/disarm
7
Audible warning
2
Door Strike
8
Courtesy
3
Strobe light
9
Switched output (timer)
4
Fail to Comm.
10 Switched output (keypad)
5
Arm/disarm/alarm
11 Computer switched output
8.34
8.34
8.34
8.34
8.34 FALSE ALARM SHUTDOWN COUNT
FALSE ALARM SHUTDOWN COUNT
FALSE ALARM SHUTDOWN COUNT
FALSE ALARM SHUTDOWN COUNT
FALSE ALARM SHUTDOWN COUNT
This function sets the amount of times the system will allow the zone
to report alarm or trouble condition (within a 2-3 hour period), before
automatically stopping any further communication from the zone.
Each zone has its own count with a range of 0 - 16. If a value of “0” is
entered, the zone will never shut down. The count is renewed after 24
hours, by the activation of another zone, or after disarming the system.
Alarm, restore, or trouble conditions are included in the shut down
count.
8.35
8.35
8.35
8.35
8.35 PROGRAMMABLE ZONE RESPONSE SELECT
PROGRAMMABLE ZONE RESPONSE SELECT
PROGRAMMABLE ZONE RESPONSE SELECT
PROGRAMMABLE ZONE RESPONSE SELECT
PROGRAMMABLE ZONE RESPONSE SELECT
Select the zones that require a different response time when the
system default of 300mS (approx 1/3 of a second) has to be
changed. The response time for these zones is programmed in item
36.