Page 20 of 28

Doc.  6001072

Rev B

2.  LIB CONNECTIONS

IMPORTANT NOTE

If the Ovation system is used in conjunction with an alarm system, the telephone line MUST
encounter the alarm system first, then the RJ71Cs, and then the Ovation Controller (see Figure
13).  If the system is not connected in this order, it will cause erratic problems with both the
alarm and Ovation systems.

Figure 13.  Connecting Alarm and Ovation Systems.

1. RJ71C Connectors

1.

Remove the shorting block from the first RJ71C connector.

NOTE:

Keep all shorting blocks with their RJ71C connectors.  Should the LIBs become damaged 
or disconnected, reinstalling the shorting blocks on their RJ71C connectors will restore 
normal telephone operation.

2.

Connect a 50 conductor cable with a 50 pin connectors from the associated LIB to the RJ71C
connector block.

Fifteen foot connector-end cables are available from Sentex.

Longer connector-end cables may be special-ordered from Sentex.

3.

Repeat steps 1 and 2 for each RJ71C and associated LIB.

IMPORTANT NOTE

If any residents have 3-way calling, either their  3-way calling service or the optional Ovation
call-waiting feature must be discontinued.  Otherwise, when call-waiting is activated, the
Ovation will trigger the 3-way calling feature and the tenant will be connected to a dial tone.  To
discontinue call waiting for a single resident, see the enclosed manual entitled "Instructions For
The Programming And Use Of The Ovation System".

2. LIB Power

1.

Connect the power cable from the supplied 12VAC transformer (or 13.5 VDC power supply you
provide) to TB2 (IN) on the first LIB.

2.

Connect TB1 (OUT) of the first LIB to the TB2 (IN) of the next LIB in the chain.

3.

Continue until all LIBs in a cabinet are connected.

CAUTIONS

1.

Do not apply power until all connections  have been made.  When power is applied to the 
LIBs, all LIB POWER indicators should light (see Figure 14).

2.

The Ovation, door strikes, and LIBs must each be powered by separate transformers.

3.

Do not overload LIB transformers by connecting more than one cabinet (10 LIBs).

Summary of Contents for Ovation S

Page 1: ... B Rev B INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FOR THE FOR THE FOR THE FOR THE S S S S AND AND AND AND V V V V MODEL MODEL MODEL MODEL OVATION SYSTEMS OVATION SYSTEMS OVATION SYSTEMS OVATION SYSTEMS ...

Page 2: ...hen you are installing the system or making changes to the system configuration TABLE OF CONTENTS BASIC INSTALLATION RULES 3 PART 1 SYSTEM OVERVIEW 4 1 OVATION CONTROLLER 4 2 LINE INTERFACE BOARDS LIBs 4 PART 2 SAMPLE INSTALLATION 6 1 SINGLE ENTRANCE 6 2 MULTIPLE ENTRANCES 7 PART 4 PHONE LINE INSTALLATION 8 1 ARRANGING TELEPHONE INSTALLATION 8 2 INSTALLING RJ71C JACKS 8 3 LIB PLANNING FORM 9 PART ...

Page 3: ...reserves the right to make changes in the products described in this manual without notice and without obligation of Sentex to notify any persons of any such revisions or changes Additionally Sentex make no representations of warranties with respect to this manual This document is protected by copyright and may not be copied or adapted without the prior written consent of Sentex Systems This docum...

Page 4: ...ing other equipment interrupt system operation Additionally each Ovation controller LIB housing and door strike must have their own individual transformer 3 DO NOT OVERLOAD THE TERMINAL BLOCKS The terminal blocks used in the Ovation system are unpluggable and the pins are soldered into the boards To connect your wires remove the head from the correct terminals and open the screws Insert the wire i...

Page 5: ...enters the resident s directory code on the controller keypad that resident s line is selected and rung The resident can talk with the visitor and allow entry at the main door or gate by dialing a 9 or at a second door or gate by dialling 5 2 Call waiting If the resident s telephone is in use two short tones will signal the visitor s call 3 If the resident dials a 2 the call in progress is put on ...

Page 6: ...tes option Controlled doors or gates can be activated from the manager s or any off site tone dial telephone door gate control requires purchase of the remote programming option 8 Remote Programming option The Ovation system can be remotely programmed from the manager s or any outside tone dial telephone 9 Remote diagnostics option The Ovation system can be accessed via any terminal using a Hayes ...

Page 7: ...connector board in the first LIB housing 2 Line Interface Boards LIBs Each LIB controls up to 12 resident telephone lines therefore a 55 unit building requires 5 LIBs Every 10 LIBs or part thereof are contained within an LIB housing located by the telephone junction box inside the building The LIBs are connected in a chain using 8 conductor flat telephone cables with an RJ45 connector on each end ...

Page 8: ...tor flat telephone cables with an RJ45 connector on each end The first LIB in this stack is connected to the MUI WARNING The LIB housing is not weather proof and MUST be installed inside a building 3 Multiple Unit Interface Each controller is connected to the Multiple Unit Interface which can accommodate up to four controllers The MUI is connected to the first LIB in the LIB stack NOTE Only one co...

Page 9: ...er Equivalence Number REN 0 1B Type of Connector Required USOC RJ71C 2 INSTALLING RJ71C JACKS Place the RJ71C jacks in series with incoming telephone lines so the Ovation can intercept the lines when a visitor wants to contact a resident Install the RJ71C jacks as follows 1 Each RJ71C jack handles 12 telephone lines so if you have a 55 unit building only 5 jacks will be needed If a unit has more t...

Page 10: ...k installation and retain a copy for programming directory codes and directory making Copy this page for additional forms Sentex recommends using the LIB address as the jack number The installer should write the jack number on the front cover of each RJ71C jack Figure 4 LIB Planning Form ...

Page 11: ...2500 feet in length NOTE Belden 8757 for unshielded installations and Belden 9504 for shielded installations or equivalent is recommended b A 2 conductor shielded cable from the Ovation Controller to the 120 VAC outlet for the 12 VAC 50 VA transformer supplied by Sentex or a 13 5 VDC power supply that you provide See Table 1 for the required wire size c A 2 conductor cable to the Ovation Controlle...

Page 12: ...transformer supplied by Sentex or a 12 VDC power supply that you provide See Table 2 for the required wire size b A 4 twisted pair cable between the connector boards of each LIB housing in the stack as shown in Figure 6 applies only to installations with multiple LIB housings NOTE Belden 8757 for unshielded installations and Belden 9504 for shielded installations or equivalent is recommended Figur...

Page 13: ...om each Ovation Controller to the 120 VAC outlets for the 12 VAC 50 VA transformers supplied by Sentex or a 13 5 VDC power supplies that you provide See Table 3 for the required wire size c 2 conductor cables from the Ovation Controller to the door strikes magnetic locks or gate operators for the 2 control relays on each controller d 2 conductor cables from the strike power supplies if required e ...

Page 14: ...he connector boards of each LIB housing in the stack as shown in Figure 8 Refer to the figure for which pairs that need to be twisted for a multiple unit installation with multiple LIB housings diagram applies only to installations with multiple LIB housings NOTE Belden 8757 for unshielded installations and Belden 9504 for shielded installations or equivalent is recommended Figure 8 Multiple Entra...

Page 15: ...ctor gently rock it from side to side while pulling on the cable 3 Remove the desired knock out 4 Mount the unit on the wall a Surface Mount Cabinets Install the two top screws bolts in the wall leaving them loose Hang the cabinet on the installed screws bolts Install the bottom screws bolts in the bottom openings Tighten all four screws bolts b Flush Mount Cabinets Cut hole in wall see Figure 9 f...

Page 16: ...lace by its own grounding screw at the top of the housing 2 Mount the LIB housing s on the wall a Install the two top screws bolts in the wall leaving them loose b Hang the cabinet on the installed screws bolts c Install the bottom screws bolts in the bottom openings d Tighten all four screws bolts 3 Ground the housing to a suitable earth ground using the ground connection located on the upper rig...

Page 17: ... installation Figure 11 LIB Types and Decade Switch Arrangements 1 SINGLE DECADE LIB SWITCH Single decade switch LIBs should be used only when there are 10 or less LIBs in your installation Set single decade switch LIB addresses as follows 1 Set LIB address numbers by working from right to left starting with the number 0 For a 10 LIB installation the decade switch on the the far right LIB will be ...

Page 18: ...e fourth LIB from the right in the second LIB housing is 023 because 02 is the housing number and 3 is the LIB number Once the LIB addresses are set determining the address of individual lines is easy For example The third line on the the fourth LIB from the right in the second LIB housing is addressed 02303 because 02 is the housing number 3 is the LIB number and 03 is the line number The elevent...

Page 19: ...connected to the negative side of the coil B LIB Control Single Unit Installations Plug the 4 twisted pair cable from the Ovation converter board into TB1 on the connector board in the first LIB housing Multiple Unit Installations Plug the 4 twisted pair cable from the Ovation converter board into TB1on the MUI in the first LIB housing Plug the four twisted pair cables from additional Ovation cont...

Page 20: ...Rev B Doc 6001072 Page 19 of 28 Figure 12 Ovation Controller Board Connections Adjustments and Indicators ...

Page 21: ...ecial ordered from Sentex 3 Repeat steps 1 and 2 for each RJ71C and associated LIB IMPORTANT NOTE If any residents have 3 way calling either their 3 way calling service or the optional Ovation call waiting feature must be discontinued Otherwise when call waiting is activated the Ovation will trigger the 3 way calling feature and the tenant will be connected to a dial tone To discontinue call waiti...

Page 22: ...Rev B Doc 6001072 Page 21 of 28 Figure 14 LIB Connections and Indicators ...

Page 23: ... short 8 conductor cables with RJ45 connectors provided with the LIBs Connect them from J1 OUT of one LIB to J2 IN of the next LIB 3 Repeat step 2 until all LIBs in the housing are connected 4 For Multiple LIB Housings connect a 4 twisted pair cable from TB5 on the MUI in the first housing to TB1 on the MUI in the next housing 5 Continue until all LIB housings are connected After you have finished...

Page 24: ...e Ovation to provide access Devices wired to ST1 and COM on TB1 activate Relay 1 Devices wired to ST3 and COM on TB2 activate Relay 2 if Relay 2 is set as a control Use shielded cable such as Belden 8771 with the shield connected to the Controller board ground screw When contact closure occurs the system activates the associated relay for the programmed period of time 3 DOOR POSITION SENSING The O...

Page 25: ...3 Enter programming step 69 followed by the three digit LIB number the two digit line number of the line you wish to use for this test and the key When you hear the tone adjust the SIDETONE BALANCE pot on the Ovation controller board to minimize the DC voltage between these two points 3 VERIFYING TELEPHONE AND DOOR GATE CONNECTIONS 1 Incoming Line Test To verify system connections each resident s ...

Page 26: ...on their telephone 2 Verify the device attached to relay 1 activates for the specified period of time and that 10 beeps are emitted from the front panel speaker 3 If there is a second door or gate connected to relay 2 call a resident from the keypad located at the front entrance to the building complex When the resident answers their telephone identify who you are and ask them to press a 5 on thei...

Page 27: ...ime C O BUSY DS6 This indicator lights when the controller calls an outside telephone number i e not a resident RINGING HOME DS7 This indicator flashes when the controller is ringing a resident POWER ON DS9 This indicator lights if power is connected to the system RELAY 2 ACTIVE DS10 This indicator remains lit while Relay 2 is activated for the programmed time 2 LINE INTERFACE BOARD LIB Line Inter...

Page 28: ...ines as it may cause harm to the network If the telephone company notes a problem they may temporarily discontinue service When practical they will notify you in advance of the discontinuation If advance notice is not feasible you will be notified as soon as possible When you are notified you will be given the opportunity to correct the problem and informed of your right to file complaint with the...

Page 29: ...ified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephon...

Reviews: