No.15S103-01
36/65
STC-MBS510U3V / STC-MCS510U3V / STC-MBS322U3V / STC-MCS322U3V
Specifications and Use
’s guide
6.2 Output Port Function
This function sets the Output to Line Mode, then the Line is assigned as the input.
The following functions can be assigned when the IO port is used as the output
The following list shows the configurable functions available through the Line Source.
The function that is described as
“Enable” on Changeable Polarity is the configurable polarity on the Line
Inverter(true, false).
No.
Function Name
Changeable
Polarity
1)
Off (Default)
-
2)
User Output
-
3)
Trigger Out
Enable
4)
Exposure End Out
Enable
5)
Frame End Out
Enable
6)
Transfer End Out
Enable
7)
Strobe Out
Enable
8)
Exposure Active
Enable
1) Off (Disable)
Disable to output the signal.
2) User Output (General Output)
Output the High or Low level signal that was previously set on the software.
3) Trigger Out (Trigger Output)
This function outputs the signal added by the Trigger Out Delay(Output pulse duration) and the Trigger
Out on Time (Output pulse width).
4) Exposure End Out (Exposure End)
This function outputs the signal added by the Trigger Out Delay(Output pulse duration) and the Trigger
Out on Time (Output pulse width) after exposure has finished.
5) Frame End Out (Sensor Readout End)
This function outputs the signal added by the Trigger Out Delay(Output pulse duration) and the Trigger Out
on Time (Output pulse width) when sensor read out is finished.
6) Transfer End Out (Transfer End Output)
This function outputs the signal added by the Trigger Out Delay(Output pulse duration) and the Trigger
Out on Time (Output pulse width) when the single image frame transfer from camera is finished.
7) Strobe Out (Strobe Output)
This function outputs the signal added by the Strobe Out Delay(Strobe output duration) and the Strobe
Out on Time (Strobe output pulse width) when the trigger signal is received.
8) Exposure Active (In Exposure Period)
Outputs the exposure timing.
(*) Actual exposure period = Output signal pulse width + Minimum exposure time 13.73 usec
Summary of Contents for STC-MBS322U3V