Half
Range
・Please carry out independent wiring of the sensor-head
aside from other power lines.
・Please refer to an attached characteristic
data sheet.
(It is when a part is not appended.)
DIN rail attachment is possible.
DIN standard:based on 46277
3m of standard coaxial cord is attached to each sensor-head.
SP(high resolution):0.03% of F.S (0.3μm, minimum)
Disconnection of a sensor-head or poor connection is detected.(NPN open-collector transistor)
250mA or less
DC12-24V
±10%
Ripple 10% or less
35~85%RH(no condensation)
CONTROLLER:-10~+60℃
SENSOR-HEAD:-20~+70℃
CONTROLLER:0.01% of F.S/℃
SENSOR-HEAD:0.02% of F.S/℃
MEASURING
RANGE
HA-30S
HA-50S
HA-80S
HA-101S
HA-141S
HA-225S
※1
※2
ITEM
※3
0~0.8mm
0~1mm
0~2mm
0~3.5mm
0~5mm
0~10mm
0~0.8V
0~1V
0~2V
0~3.5V
0~5V
0~10V
±1% of F.S
※4
0.03% of F.S (0.3μm, minimum)
※5
DC~10kHz
(-3dB)
52Ω
※6
※8
●
記号
型式
A
B
C
HA-30S
HA-50S
HA-80S
3.6
2.6
5.4
3.2
8
15
15
15
3.2
・HA-101S、141S
3
B
C
・HA-30S~80S
・HA-225S
φA
B
φC
・HA-162S
6
14
5
3
φ3.2
φ3.2
対辺21
M16,P=1.0
・HA-222R
14
8
18
φ3.2
対辺19
M14,P=1.0
22
5
.
5
5
.
5
3
.
8
4
3
4
.
5
22
φ2.6
2-φ3.5
2-φ6
0 0 0 0
Voltage-meter
Target
(2)SPAN-Adjustment
Please contact a sensor at a target.
Please turn 0-ADJ so that analog output voltage
becomes 0V.
Target
Please set a sensor-head as the distance of the
half of the measurement target range.
Please rotate SPAN-ADJ so that you may become a
voltage value suitable for the distance.
(ex 1mm=1.000V)
NOTES)Please repeat ZERO-ADJ and SPAN-ADJ
2to3 times.
Controller
Sensor
head
記号
型式
A
B
C
HA-101S
HA-141S
M10,P=1.0 12 3
5
15
D
14
19
M14,P=1.0
A
対辺D
(unit:mm)
3
(unit:mm)
- +
V13231
S P A N
0-ADJ
POWER
DZ
ALARM
SC
TC
LS-700
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨
⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰ ⑱
※7
S P A N
0-ADJ
POWER
DZ
ALARM
SC
TC
LS-700
5 4
S P A N
0-ADJ
POWER
DZ
ALARM
SC
TC
LS-700
0 0 0 0
Voltage-meter
Controller
Sensor
head
S P A N
0-ADJ
POWER
DZ
ALARM
SC
TC
LS-700
①
②
③
④
⑤
⑥
⑦
①Power indicator
②Alarm indicator
③Span-adjustment trimmer
④Zero-adjustment trimmer
⑤Digital zero control
changeover switch
⑥Digital zero indicator
⑦Digital zero switch
14
.
5
6 1
(1)ZERO-Adjustment
(When 0-ADJ is used.)
Thank you for purchasing this product.
In order to use this specification, fully satisfying
it, please use a handling description on looking well.
CE-Marking Correspondence article EMC directive (2004/108/EC):EN61000-6-4(EMI),EN61000-6-2(EMS).
The test is not application to D.C power input ports intended to be permanently connected to cables less than in
10m length.
Please make into a length of less than 10m the code which connects a controller with a direct-current power supply.
There is no compatibility between sensors-head.
Change of the length of the code of a sensor changes the characteristic. (The standard length is 3m.)
When length is changed, please contact our sales department.
It is the case where an adjustment subject is iron.
The material of iron of our standard adjustment subject is SS400.
When an adjustment object is not iron, The lineality of LS-700-08 is set to of ±2% of F.S.
LPF (Low Pass Filter) the static minimum at the time of use-it is resolution Please specify SP type of an option.
A standard machine is of F.S 0.1% (1μm of resolution [Minimum]).
It is the case where the length of coaxial cord is standard specification (3m), and an adjustment subject is iron.
It is chosen whether digital zero are controlled by the digital zero control changeover switch of a panel side with
digital zero switch of a panel side, or digital zero terminal performs.
When a changeover switch is made into the SC side, it becomes control with digital zero switch, and when it turns
on the TC side, it becomes control with digital zero terminal.
When controlling digital zero by digital zero switch, once it pushes digital zero switch, the digital zero function
will operate, and it will be canceled if it pushes once again.
When controlling digital zero by digital zero terminal, it will be canceled, if digital terminal and COM terminal
are short-circuited and digital zero function will operate and open.
During digital zero functional operation, the digital zero indicator beside digital zero switch lights up.
At the time of detection, the alarm indicator of a panel side lights up.
DIGITAL ZERO FUNCTION
The present output value is made into zero.
Error ±0.1% of F.S
ALARM OUTPUT
OUTPUT
VOLTAGE
LINEARITY
RESOLUTION
RESPONSE
OUTPUT
IMPEDANCE
STABILITY
AMBIENT HUMIDITY
AMBIENT TEMPERATURE
POWER
CONSUMPTION
OPTION
DC12-24V
POWER
Analog
V - O U T
DC40V
100mA
※Nothing connects with
③ and ④ terminal.
Digital zero
control terminal
Alarm output
5mm or more
Use a flat tip M3 screw to secure the sensor-head
.
N
otes)When the sensor-head of HA-162S and HA-222R is embedded,
please contact our sales department.
2 -t hro ug h bo re f or M 4
・Since the controller is adjusted according to the
sensor-head, use which changes other sensor-head
and cable length of form cannot be performed.
・Since there is fear of mutual interference when
using it, making a sensor-head approach, please
contact our sales department.