Installation of cable at gates
5 - 14 • • • Intelli-FLEX II product guide
cable length must be added to the total amount of non-sensitive feed cable used
in the zone. This total length must not exceed that the non-sensitive feed cable
lengths. See
Table 4-1, Non-sensitive feed cable lengths,
This bypass is used in all applications that use the gate
bypass module.
Installation instructions
1. Install the sensor cable on the fence in the usual manner.
2. Cut the a piece of PVC conduit to the required length:
Length of bypass cable = (width of gate + 2 X 25 cm [10 in.]) + (2 X 45 cm
[18 in.])
3. Bury the conduit to a depth of 45 cm (18 in.)
4. Cut the required length of non-sensitive feed cable:
Length of bypass cable = (width of gate + 2 X 25 cm [10 in.]) + (2 X
mounting height of sensor cable) + (2 X 45 cm [18 in.])
5. Pull the bypass cable through the buried conduit.
6. Join the bypass cable to the sensor cable using the required junction devices.
See “Cable devices” on page 34 for installation details.
7. Seal the ends of the conduit.
Swinging gate without cable protection
Figure 5-15 Swinging gate without protection
no protection on gates
cable bypass