Silver Network wiring connections
Silver Network specifications
•
Data rate - fixed 57.6 k bps
•
Maximum 60 devices spread over up to 4 independent network loops
•
Two communication Channels (Side A, Side B)
•
Response time - 0.5 seconds, or less from alarm source to Network Manager (per loop)
•
Network termination - not required
•
Transmission media/maximum separation distances between processors:
•
EIA-422 copper wire - 1.2 km (0.75 mi.) - 2 pairs per Channel
•
Multimode fiber optic cable (820 nm) - 2.2 km (1.4 mi.) - 2 fibers per Channel - optical
power budget 8 dB
•
Singlemode fiber optic cable (1310 nm) - 10 km (6.2 mi.) - 2 fibers per Channel - optical
power budget 8 dB
•
Ethernet - Category 5 cable, 100 m between PoE switch and processor location
Figure 67: FlexPS processor wiring diagram
Note
A network interface card must be installed on the FlexPS
processor for the processor to use network communications.
T8
T4
sensor cable
T8
T4
T9
-
+
T10
AUX 1
- +
AUX 2
- +
RELAY 1
NC COM NO
RELAY 2
NC COM NO
RELAY 3
NC COM NO
RELAY 4
NC COM NO
FLEX CHA
- +
FLEX CHB
- +
FLEX AUDIO
POWER
T9
T10
relay outputs
self-test
auxiliary inputs
power
input
A-side B-side audio output
- DC GND
+ 12 to 48 VDC
auxiliary/self-test
audio activation inputs
-
+
AUX input 1
-
+
AUX input 2
relay 1 NC
relay 1 COM
relay 1 NO
relay 2 NC
relay 2 COM
relay 2 NO
relay 4 NO
relay 4 COM
relay 4 NC
relay 3 NO
relay 3 COM
relay 3 NC
audio O/P
+ center conductor
- shield
Flex Ch B
+ center conductor
- shield
Flex Ch A
audio activation