Installing the sensor cable
FlexPS Product Guide
Page 27
•
Attach the sensor cable at least 30 cm (1 ft.) away from horizontal support bars and other
cables.
•
For added security use one or two steel cable ties or pieces of steel wire per fence panel.
•
For a single cable pass, attach the sensor wire to the middle of the fence.
•
Use Armour-FLEX if the cable is being installed in an area where it may be prone to damage
from vandalism, equipment, or materials.
•
Using UV resistant polypropylene cable ties, secure the cable to the fence fabric at the
midpoint of the chain-link. Install the cable ties by hand, tightening them enough to hold the
cable securely against the fence.
Bend radius
•
The smallest allowable bend radius for MEX sensor cable is 4 cm (1.5 in.).
•
The smallest allowable bend radius for Mark 2 sensor cable is 7.5 cm (3 in.).
•
The smallest allowable bend radius for Armour-FLEX sensor cable is 15 cm (6 in.).
Note
During installation at sub-zero temperatures (0º C, 32º F), the plastic
cable ties may become brittle and subject to failure.
Figure 17: Securing cable to a chain-link fence
Figure 18: Smallest allowable bend radius
attach the cable to the fence
fabric in the middle of a
DO NOT attach the cable to the fence
use two steel wire ties on each
fence panel for additional security
attach the wire ties snugly
fabric at the junction of 2 fence wires
fence wire
4 cm
15 cm
15 cm
30 cm
MEX sensor cable
Armour-FLEX cable
Mark 2 sensor cable
(MEX and Mark 2)
7.5 cm
8 cm