SENSTAR Flare Maintenance Manual Download Page 10

 

PPD Maintenance Manual 

 

T1DA0502-002, Rev A 

 

Page 10 

4.2 

Connect Adapter Box (dongle) to PC 

 
Connect the dongle to the PC using a 9 Pin EIA-232 straight-through cable maximum length of  
3 m (10 ft.). Connect the adapter to the appropriate COM port on the PC on which the 
Transmitter Programmer software has been installed. The DB-style connectors can only be 
plugged in, in one orientation. Gentle pressure is all that is required. If excessive force is needed, 
the connector and plug may not be properly aligned and continued force may damage or break 
the connector pins.  
 

4.3 

PPD Battery Removal 

 
The PPD programming interface connector is located in the battery compartment. Remove the 
battery cover (Figure 4.3). Only remove the battery cover at a workstation equipped with 
electrostatic discharge (ESD) protection since static sensitive components are exposed. The 
battery cover is fastened with security screws requiring a Torx security driver bit. 
 
Remove the battery from the battery compartment by gently tapping the transmitter case against 
the palm of the hand while the battery cover is removed. The battery will fall into your hand, 
retained by the flying leads of the battery clip. Carefully unsnap the battery clip and set the 
battery aside. 

 

 

 

battery cover screw
locations (4 per unit)

Figure 4.3 PPD Battery Cover Removal 

 

4.4 Attaching 

adapter board to PPD 

 
The adapter board is inserted into the programming connector located in the bottom of the 
battery compartment shown in Figure 4.4. Note the notch guides on each side of the battery 
compartment opening. The adapter board is made to fit into these guides to aid in aligning the 

Summary of Contents for Flare

Page 1: ... Phone 1 613 839 5572 1 510 249 1450 44 1386 834433 49 7544 95910 52 777 313 0288 Toll Free 1 800 676 3300 Fax 1 613 839 5830 1 510 249 1540 44 1386 834477 49 7544 959129 52 777 317 0364 Website www senstar com E mail info senstar com All material including technical data designs knowledge and ideas contained in this document are considered proprietary and the exclusive property of Senstar Corpora...

Page 2: ...y name and logo change combine PPD Maintenance and Technical Manual T1DA0502 with PPD Programmer Operation Manual T1DA0602 Flash is a trademark of Magal Senstar Inc and is used under license by Senstar Corporation Flare is a registered trademark of Magal Senstar Inc and is used under license by Senstar Corporation Senstar and Senstar Stellar are registered trademarks of Senstar Stellar Corporation...

Page 3: ...9 4 1 PROGRAMMING ADAPTER BOARD 9 4 2 CONNECT ADAPTER BOX DONGLE TO PC 10 4 3 PPD BATTERY REMOVAL 10 4 4 ATTACHING ADAPTER BOARD TO PPD 10 4 5 PROGRAMMING 11 4 6 RESET LOW BATTERY IN LEGACY PPDS 13 4 7 AFTER PROGRAMMING 13 5 0 PPD COMMUNICATIONS RECOVERY 13 6 0 MAN DOWN MODULE 14 6 1 PROGRAMMABLE OPTIONS 14 6 1 1 Alarm Type 14 6 1 2 Alarm Repeat Period 14 6 1 3 Tilt Angle for Alarm 15 6 1 4 Time B...

Page 4: ...MDM 18 7 0 PPD MAINTENANCE 20 7 1 CARE AND CLEANING 21 7 2 PPD ACCESSORIES PARTS AND OPTIONS 21 7 3 BATTERY CONSIDERATIONS 21 7 3 1 Battery Life Specification 21 7 3 2 Battery Life Considerations 21 7 3 3 Battery Replacement 22 8 0 PPD TRANSMITTER SPECIFICATIONS 23 ...

Page 5: ...ons for PPD units as well as PPD maintenance 1 1 Scope This manual is intended for use by qualified service technicians who are responsible for the maintenance of the personal alarm system This manual assumes that the reader has a basic knowledge of electronics and Windows O S PC operation and is familiar with the system operation and configuration 1 2 Related Documentation The following additiona...

Page 6: ...ures such as pull pin and man down module tilt alarms For each of these there are ini settings which must be set before any ID programming is performed Note that the ini settings used in setting PPD IDs Transmitter Programmer ini must match the corresponding settings in the system ini file 2 1 1 PPD Offsets The PPD offset is a value that is added to the ID set via the Transmitter Programmer softwa...

Page 7: ...ystem will examine the incoming PPD transmit ID value subtract the PPD offset and compare the result to the minimum and maximum ID values in its ini file In this way the system will determine if the received alarm is a low battery alarm If it is a low battery alarm the system will subtract the low battery offset and display the correct PPD ID Newer PPD firmware program code version 3 00 and above ...

Page 8: ... X XY is the release version There is also an install notes file supplied to help guide the installation If desired add a desktop shortcut to the application after installation 3 3 Configure the INI File This section describes the configuration of the TxProgrammer ini file that must be completed before attempting to program PPDs Do this BEFORE programming any PPDs All PPD units at a facility must ...

Page 9: ...an interface that connects between the PC and the PPD being programmed The interface assembly consists of a straight through serial cable and the adapter box dongle and adapter board T1BA0800 interconnected by approximately 24 in of 20 conductor ribbon cable The adapter board is fragile and should be handled carefully Particular caution should be exercised to avoid bending or breaking the adapter ...

Page 10: ... the battery cover at a workstation equipped with electrostatic discharge ESD protection since static sensitive components are exposed The battery cover is fastened with security screws requiring a Torx security driver bit Remove the battery from the battery compartment by gently tapping the transmitter case against the palm of the hand while the battery cover is removed The battery will fall into...

Page 11: ...press the Get Info button The result will be a screen as shown in Figure 4 5 The information presented on the left was read from the connected PPD this info is also stuffed into the user edit fields on the right The PPD firmware version is also displayed Version 4 00 supports 14 bits of modulation so although read from the PPD the Low Battery ID is not used Also on the right is the PPD ID Offset r...

Page 12: ...operation is not shown in the list of available choices consult the factory After programming is successful the data is read from the PPD to verify settings Note that if the PPD has 12 bit modulation firmware verify the Low Battery ID read from the unit is appropriate based on your site low battery offset If not recheck the ini settings and re start the application The following message box may ap...

Page 13: ... with the PPD ID using non removable labels paint nail polish or engraving 5 0 PPD COMMUNICATIONS RECOVERY If the program cannot communicate with the PPD then the following error window will be displayed If this occurs because the connection is to an old 6 volt PPD select OK Otherwise cycle turn off then turn on the PPD Programmer dongle power and reselect the Get Info button Also try cycling powe...

Page 14: ...best performance for their specific operational requirements 6 1 1 Alarm Type The Man Down module has three modes of re transmit operation Single Alarm Retransmit until Manual Reset Retransmit until Auto Reset Unit is no longer tilted Single Alarm The PPD will transmit a single alarm each time the unit re enters the tilt alarm mode Retransmit until Manual Reset The PPD will transmit an alarm each ...

Page 15: ...quently emit warning tones when the wearer walks or is engaged in any activity that may cause motion of the PPD A value in the range of 3 5 is more practical for most applications 6 1 5 Alarm Time After Warning The value of this parameter determines how long the unit waits after starting the warning tones before it transmits an alarm message If the unit is accidentally tilted this value sets how l...

Page 16: ... Man Down Menu Item from the Transmitter Programmer main screen 6 2 1 Access Man Down Feature Dialog In the Upper left corner of the PPD Programming Software main screen is a pull down menu item labeled Man Down Click on this menu and then select the choice Program Man Down Module The man down programming dialog box will be displayed 6 2 2 Entering Parameters Figure 6 2 2 shows the man down module...

Page 17: ...rogramming success If desired you can select Get Info to read the parameters from the MDM Select Done to close the Man Down programming dialog and return to the Transmitter Programmer Main Screen Perform the after programming steps outlined in section 4 7 6 2 4 Get Info It is sometimes useful to determine how a particular man down module has been programmed The Get Info function allows you to read...

Page 18: ...he PPD MDM unit must be positioned perpendicular both upright and inverted to the earth s surface The maximum angle error must be no greater than five degrees The surface used to position the PDP MDM unit must be stable and vibration free Any tilt shock jitter or vibration during the calibration cycle will introduce errors into the measurements If the unit is equipped with a pull pin the ARP must ...

Page 19: ...ce The program will then display the following prompt box Place the PPD MDM unit upright and perpendicular to the earth s surface as shown in figure to the right and then select the OK button gravity direction Earth s surface The program will then display the following prompt box Place the PPD MDM unit inverted and perpendicular to the earth s surface as shown in figure to the right and then selec...

Page 20: ... the Man Down programming dialog and return to the Transmitter Programmer Main Screen Perform the after programming steps outlined in section 4 7 If any result is OUT OF RANGE then the unit must be re calibrated Out of range can be the result of poor position or vibration during the calibration sequence If the unit repeatedly fails calibration submit the PPD with the MDM for repair After a success...

Page 21: ... Pin and Man Down Configurable Options Programming Adapter Board for 9v PPD T1BA0800 Programming Adapter Board for 6v Legacy PPD T1BA0900 Battery cover TorxTM security screws and driver bit Size T8 McMaster Carr 7233A61 7 3 Battery Considerations 7 3 1 Battery Life Specification The PPD DC power source is a 9 volt alkaline battery The end of life of the PPD battery is defined as the point at which...

Page 22: ...e is defined as follows for a PPD with the Man Down Module option One year of continuous operation at room temperature assuming no manual activations or automatic activations due to tilt during the year Following the one year under these conditions the unit will be capable of automatically activating due to a tilt or manually activating using the pushbutton D Hours of Standby Operation The standar...

Page 23: ...s and battery manufacturer instructions 8 0 PPD TRANSMITTER SPECIFICATIONS The PPD operational frequency is programmable within two separate bands There is a PPD model for each band The low band 420 450MHz is model T1FG02XX and the high band 450 470 MHz is model T1FG03XX The XX defines options such as antenna external internal Pull Pin and Man Down Module The transmission duration is 250 msec Mode...

Reviews: