RailPilot system manual
11
2.2 PC-Software FR85-2 ILLG protocol tester
The software must first be successfully installed on the PC.
RailPilot FR 85-2 ILLG – S1L5 is connected to the PC as previously described.
Once the software has been started-up, the following
window appears:
Once the software has been started-up, the following
window appears.
Then the ComPort number must be set to that of the
ComPort in use.
The following windows appears when the
"
Send
"
menu is selected:
Special feature:
There is the problem that it is possible to set a baud-
rate which cannot be processed on a PC.
In order to bypass this problem, the following
function has been integrated in RailPilot
FR 85-2 ILLG – S1L5:
Once the power supply has been switched on, the
sensor monitors its RS485 interface with a baudrate
of 57.6 kBaud for 100 ms and tries to receive
the command
"
C
"
.
If the command
"
C
"
is received within 100 ms, the
sensor knows that it is connected to a system which
operates with 57.6 kBaud. The sensor maintains the
baudrate of 57.6 kBaud.
If the command
"
C
"
is not received within 100 ms,
the sensor knows it is not connected to a system
operating with 57.6 kBaud. It then switches to its
pre-set baudrate.
In order to create a serial connection to RailPilot FR 85-2 ILLG – S1L5, proceed as follows:
1. Disconnect FR 85-2 ILLG – S1L5 from the power supply.
2. Activate the
"
continuous
"
button (the command
"
C
"
is continuously sent).
3. Reconnect FR 85-2 ILLG – S1L5 to the power supply.
Should no connection be made, repeat steps 1 … 3.
1.
Enter the number of the
ComPort in use here.
2.
Activate the
"
Zuweisen
"
button.
3.
It is then possible to switch to
the “Send“ menu.