ENGLISH
Pag. 35
Visualised mes-
sage
Possible cause
Corrective action
EI2C
There is no communication
between the sensor head and
the microprocessor base board
of SMART 3
Please check that the detector is not
installed in environments with a tem-
perature over 60 °C. If so, change the
detector installation position. If the
problem is still present replace the
sensor head with a new one.
EAMP
The SMART3 detector main bo-
ard does not match the sensor
head connected (doesn’t match
the serial number inside). May
be that the heads between two
different detectors are inverted.
Check that the serial number printed
on the sensor head it is the same that
the one printed on the detector label.
EBCH
The dip switches (1 & 8) for the
data recovery of the detector
are in the wrong position
Please set the dip switches for data re-
covery in the right position, following
the technical manual.
8. Repair
Repair from the user side is not allowed; the user has to return the entire equipment to the
manufacturer with the warranty coupon for repairing in paragraph 11. For further informa-
tion see EN 60079-19 standard.
9. Packing instructions
To grant a stout protection against impacts we recommend using the original package or
protect the device with bubble wrap sheets.