INSTRUCTION MANUAL

 

TEMPERATURE SWITCHES  
TSZ3H-24

  

These temperature switches with display are designed for using as two-state 
controller (on/off type control) for compare the temperature set-point with the 
actual temperature value in range -

50 to 250°C, with the possibility of 

switching

 the electrically isolated contacts of a connected relay

 

 

Summary of Contents for TSZ3H-24

Page 1: ...Section C File 13728 sensit sensit cz www sensit cz 5407 1 01 17 Supersede INSTRUCTION MANUAL TEMPERATURE SWITCHES TSZ3H 24 These temperature switches with display are designed for using as two state controller on off type control for compare the temperature set point with the actual temperature value in range 50 to 250 C with the possibility of switching the electrically isolated contacts of a co...

Page 2: ...he set temperature interval and the second relay is switched at the exceeding set emergency temperature only one sensing element is used the switch operates as a single controller which switches each relay by the set temperature interval only one sensing element is used the switch operates as a double controller it means that each relay is controlled by the temperature of one sensing element the s...

Page 3: ...rail The material of the plastic box is LEXAN RESIN EXL 5689 Switches installation 1 Place the converter to the DIN standard rail using a grip which is a part of the plastic box 2 Connect the cable from resistance sensor Pt 100 3850 or Ni 1000 6180 and from power supply into appropriate terminals according to wiring diagram Connect the cable to the output relay contacts according to the wiring dia...

Page 4: ...ters Adjustable parameters are cyclically switched over by means of holding the button SW1 The number of the parameters is dependent on the selected function of the switch First a parameter indicator is displayed for example Fnc rt1 and afterwards its set value is indicated As the first the type of function parameter Fnc is always set A characteristic of relay switching can be set by means of hard...

Page 5: ...ng element1 rt1 temperature difference dtL1 tL1 temperature difference dtH1 tH1 sensing element2 rt2 temperature difference dtL2 tL2 temperature difference dtH2 tH2 brightness bri Note sensor Rt2 is not used in functions 01 and 02 relay1 contacted interconnection of the terminals 1 3 relay2 contacted interconnection of the terminals 4 6 the relay can be set as short or break for all function The d...

Page 6: ...roundings 10 to 80 atmospheric pressure 70 to 106 kPa Storage Ambient temperature 5 to 40 C Humidity 5 to 85 Delivery Each delivery contains the following unless otherwise agreed by the customer Converter according to purchase order Instruction Manual including Guarantee Certificate Delivery Note Likvidace SENSIT s r o has signed an agreement with the Company RETELA s r o on the collective perform...

Page 7: ... damaged as a result of normal use of the product without loss of its operational characteristics and guaranteed technical parameters Into which unskilled intervention unauthorised structural or other changes reprogramming resetting of set parameters etc have been made That is mechanically damaged e g by fall being hit by a hard object cleaning with unsuitable agents power cord tearing breaking br...

Reviews: