![Sensata Dimensions 12LP15 Owner'S Manual Download Page 25](http://html1.mh-extra.com/html/sensata/dimensions-12lp15/dimensions-12lp15_owners-manual_1243177025.webp)
Page 25
Default Configuration
Model
Local
Switch
Remote
Switch
Low
Battery
Shut
Down
Timer
Load
Sense
AUX
Control
Battery
Type
Branch
Circuit
Rating
AC Line
Qualify
CAN
Instance
CAN
Baud
Rate
LP Standard
Enabled
Momentary
10.5 V
Off
Off
Disabled
N/A
N/A
N/A
1
250 k
LP with “R”
Suffix
Disabled
Snap
10.5 V
Off
Off
Disabled
N/A
N/A
N/A
1
250 k
LPC Standard
Enabled
Momentary
10.5 V
Off
Off
Disabled
AGM
15 A
30 Secs
1
250 k
LPC with “R”
Suffix
Disabled
Snap
11.0 V
Off
Off
Disabled
AGM
20 A
30 Secs
1
250 k
Setting Options (Set by NVM Setup Utility or Factory)
Options
Local
Switch
Remote
Switch
Low
Battery
Shut
Down
Timer
Load
Sense
AUX
Control
Battery
Type
Branch
Circuit
Rating
AC Line
Qualify
CAN
Instance
CAN
Baud
Rate
Enabled
Momentary
10.5 V
Off
On
Disabled
Wet
Disabled
5 Secs
1
250 k
Disabled
Snap
to
30 Min
Off
RV
AGM
5 A
to
to
500 k
12.0 V
60 Min
Utility
GEL
to
30 Secs
13
Control
20 A
Increments
0.1 V
Steps
5 A Steps
5 Sec
Steps