Remote Inverter “On/Off” Switch
Remote Inverter “On/Off” Switch Installation – Customer Supplied
For non “-R” suffix versions, a momentary switch must be used. In non-remote only mode, the momentary switch
will toggle the inverter state between on and off, or standby and off while in charge mode. The remote switch may
be customer supplied or ordered separately from the factory.
For remote only “-R” suffix versions, a snap switch must be used. If a snap switch is used in place of a momentary
switch, the inverter may not correctly respond. In remote-only mode, the snap switch will turn the inverter on and
off when in inverter mode. When in charger mode, it will switch the inverter state between off and standby.
1.
Mount the remote switch in a convenient location.
2.
Using 18 AWG wire and an insulated ¼” female faston, wire between the “Remote On/Off ” connection on the
left side of the inverter.
3.
Wire from the remaining connection on the remote switch to the battery positive (+) terminal.
4.
Install a 5 A in-line fuse in series within 18 inches from the positive (+) terminal of the battery.