Sensa-Heat HPPI09 User Manual Download Page 1

 

 
 

 

 

 

 

 

PI Series 

INVERTER POOL & SPA HEAT PUMP 

 

 

 
 
 
 
 
 
 

USER MANUAL 

 

 

Summary of Contents for HPPI09

Page 1: ...PI Series INVERTER POOL SPA HEAT PUMP USER MANUAL...

Page 2: ...t modes 5 3 6 Technical parameter 6 3 7 Dimensions 7 4 Installation guidance 8 4 1 Installation reminder 8 10 4 2 Wiring 11 4 3 Electric wiring diagram 11 4 4 Reference for protecting devices Cable Sp...

Page 3: ...ur PI Series Heat Pump Thank you Model Number_____________________________________ Serial Number_____________________________________ Date of Purchase___________________________________ Invoice Number...

Page 4: ...s attention to a procedure practice or the like which if not correctly performed or adhered to could result in personal injury or injury to a third party These signs are rare but are extremely importa...

Page 5: ...to accelerate the defrosting process or clean the frosted parts i If a repair is required please contact the nearest after sales service center The repair process must be strictly carried out in accor...

Page 6: ...a Always keep upright b Do not lift the heat pump by the water unions as this may cause internal damage to the titanium heat exchanger inside the heat pumps 3 2 Accessories Connection of the condensat...

Page 7: ...ange a Air temperature operating range 10 C 43 C b Heating temperatures setting range 18 C 40 C c Cooling temperature setting range 12 C 30 C d The ideal ambient air temperature for best performance i...

Page 8: ...0 26 1 82 0 32 2 51 0 38 2 92 0 5 3 84 Rated input current A 0 83 5 98 1 13 7 83 1 39 10 9 1 65 12 7 2 17 16 7 Power cord mm 3X2 5 3X2 5 3X4 3X4 3X6 Sound level at 10m dB A 16 8 26 1 20 1 28 7 21 1 3...

Page 9: ...n s installation and layout reference only The product is subject to adjustment periodically for improvement without further notice A B C D E F G H HPPI09 410 645 390 430 890 250 75 657 HPPI13 410 645...

Page 10: ...rios b The heat pump should be installed in an outdoor location with adequate ventilation Installing a heat pump without adequate ventilation will result in poor performance or damage to your heat pum...

Page 11: ...he pump filter and before the chlorinator sanitizer Please note Water connection locations may differ from the diagram this diagram is to be used as a guide only The inlet and outlet water unions must...

Page 12: ...er The recommended pump must meet required flow rates as per the Technical Parameter Max lift 10m 4 When the heat pump is running there will be condensation water discharged from the bottom of the hea...

Page 13: ...g devices and cable specification Above data is subject to modification without notice Note The above data is based on power cables less than 10m long If the power cable required is more than 10m wire...

Page 14: ...lock Screen 2 Heating mode 18 40 C 3 Cooling mode 12 30 C 4 Auto mode 12 40 C 1 Boost 2 Silence Temperature Setting Attention i The controller has power down memory function ii The buttons will turn d...

Page 15: ...Press to switch among boost mode silence mode Default mode boost Please choose boost mode for initial heating e Wi Fi When the screen is on press for 3 seconds after flashing enter Wi Fi connection C...

Page 16: ...e 5 Running status checking table Symbol Content Unit C0 Inlet water temp C C1 Outlet water temp C C2 Ambient temp C C3 Exhaust gastemp C C4 Evaporator coil pipe temp C C5 Return gas temp C C6 Cooling...

Page 17: ...with the refrigerant and corrode the copper pipe d Vacuumize completely before welding Welding can only be carried out by professional personnel e Please stop using while gas leakage occurs and contac...

Page 18: ...ections regularly 4 If repair or removal is required please contact authorized service center nearby 5 Do not attempt to work on the equipment by yourself Improper operation may cause danger 6 To redu...

Page 19: ...ntenance operation f Vacuumize completely before welding Welding can only be carried out by professional personnel in service center Failure solution and code Failure Reason Solution Heat pump does no...

Page 20: ...mode 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failu...

Page 21: ...er Pump Control Connection Remote control switch connector Breaker fuse Earthing Power Supply 230V 50Hz Water pump 230V voltage 500W capacity Water Pump Breaker fuse Power Supply 230V 50Hz Earthing Po...

Page 22: ...20 Remote control switch connector Water pump 230V voltage 500W capacity Breaker fuse Earthing Power Supply 230V 50Hz Water Pump Breaker fuse Power Supply 230V 50Hz Earthing Contactor Power Cord...

Page 23: ...tion 1 Water pump timer 2 Water pump wiring of Heat Pump Note The installer should connect 1 parallel with 2 as above picture To start the water pump condition 1 or 2 is connected To stop the water pu...

Page 24: ...22 10 Wi Fi operation...

Page 25: ...23...

Page 26: ...24...

Page 27: ...25...

Page 28: ...26...

Page 29: ...27...

Page 30: ...d by Spa Craft had repairs attempted or made by other than Spa Craft or its authorized dealers been subject to abnormal conditions such as incorrect voltage supply lightning or high voltage spikes or...

Page 31: ...AQ43ASC R32 P2...

Reviews: